beautypg.com

DME Heaters and Auto-Fixed Integral Heater Distributor Probes User Manual

Refer to mini-print no. 1700, End cap for distributor tube, Distibutor tubes

background image

Please read carefully before installing components.

ME-0725-PS-215-B 09-08 FDP/ID

INSTALLATION DATA FOR MICRO SERIES DISTRIBUTOR TUBES,

REFER TO MINI-PRINT NO. 1700

END CAP, HEATERS AND AUTO-FIXED

"INTEGRAL HEATER"

DISTRIBUTOR PROBES, END CAPS.

R

LENGTH

0.628

DIA.

0.03 x 45

0.375

DIA.

DANGER

WARNING

out residual moisture before applying full power. Failure to do so may cause

IMPORTANT SAFETY INFORMATION

A hot-runner system includes electrical elements and may contain molten
plastic at elevated temperature and pressure. To avoid injury, exercise
caution by reading these instructions before servicing or operating the
system.
These instructions must be passed on to the end user where they should
be read before using this product. Failure to do so can result in serious
injury or death.

Failure to comply can result in serious injury or death:
STORED ENERGY AND HIGH TEMPERATURE HAZARDS
This product maintains molten plastic at high pressure. Use caution when
operating and servicing the system.
Physical contact with molten plastic may result in severe burns. Proper
protective equipment, including eye protection, must be worn. This product
has heated surfaces. Use caution when operating and servicing the system
to avoid severe burns. Proper protective equipment should be worn.

Failure to comply will result in serious injury or death:
ELECTRICAL HAZARDS
Improper voltages or grounding can result in electrical shock. Use only
with proper voltage and a proper earth ground.
To avoid electrical shock, do not operate product when wet.
Do not operate this equipment with covers or panels removed.
To avoid electrical shock, turn off main power disconnect and lockout /
tag out before servicing this device. Do not connect temperature sensors to
electrical power. It will damage the product and it can cause fire, severe
injuries or even death.
If green ground wire present wire must be connected to the ground.
Do not rebend rigid leads. Rebending leads might result in damage to circuit.
Product might absorb moisture when cool. Use low Voltage or power to drive

damage to this product.

PURPOSE. IN NO EVENT SHALL D-M-E BE RESPONSIBLE FOR LOSS OF USE, REVENUE

D-M-E SHALL NOT BE LIABLE FOR MISUSE OR FAILURE TO FOLLOW THE ENCLOSED
INSTRUCTIONS AND SPECIFICATIONS. D-M-E HERBY TO DISCLAIMS ALL IMPLIED
WARRANTIES, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR

OR PROFIT, OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGED.

0.750

0.14 RAD.

0.629

0.000

+0.002

DIA.

0.562

1.000

1.125

-0.002

0.000

DIA.

O.A.L.

HEATED AREA

1"

NO HEAT AREA

0.375 DIA.

Note: Dimensions shown in Inches.

(240 VAC, T/C TYPE J, 34" LEADS)

THERMOCOUPLE (T/C) DISTRIBUTOR TUBE HEATERS

BLACK IS POSITIVE (+) AND IRON (MAGNETIC)

WHITE IS NEGATIVE (-) AND CONSTANTAN (NON-MAGNTIC)

T/C LEADS - BLACK & WHITE

HARDNESS:28-35 HRc

MATERIAL: AISI 4140 STEEL OR EQUIVALENT

END CAP FOR DISTRIBUTOR TUBE

MATERIAL: AISI 4140 STEEL OR EQUIVALENT

DISTIBUTOR TUBES

POWER LEADS - MULTICOLOR

CAUTION: HANDLE LEADS WITH CARE.

WIRING INFORMATION

THREAD

1/2-13

15.76

HT-05-03-16

EC-11-05

CATALOG NUMBER

11.82

HT-05-03-12

LENGTH

CATALOG NUMBER

CATALOG NUMBER

810

14.0

13.0

HCTC-03-13

760

13.0

12.0

HCTC-03-12

720

12.0

11.0

HCTC-03-11

710

11.0

10.0

HCTC-03-10

650

10.0

9.0

HCTC-03-9

550

9.0

8.0

HCTC-03-8

515

8.5

7.5

HCTC-03-75

480

8.0

7.0

HCTC-03-7

470

7.5

6.5

HCTC-03-65

450

7.0

6.0

HCTC-03-6

430

6.5

5.5

HCTC-03-55

400

6.0

5.0

HCTC-03-5

340

5.5

4.5

HCTC-03-45

320

5.0

4.0

HCTC-03-4

WATTS

O.A.L.

HEATED AREA