DME Standard Bayonet Thermocouples User Manual

Bayonet adaptor

background image

PURPOSE. IN NO EVENT SHALL D-M-E BE RESPONSIBLE FOR LOSS OF USE, REVENUE

D-M-E SHALL NOT BE LIABLE FOR MISUSE OR FAILURE TO FOLLOW THE ENCLOSED
INSTRUCTIONS AND SPECIFICATIONS. D-M-E HERBY TO DISCLAIMS ALL IMPLIED
WARRANTIES, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR

OR PROFIT, OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGED.

X

0.438 DIA.

REF.

REF.

0.375

BAYONET ADAPTOR

0.281 DIA. HOLE

(T/C LENGTH)

L

(HOLE DEPTH)

A

0.188 DIA. TUBE

BAYONET ADAPTOR

TAP DEPTH TO MEET WITH

EDGE OF MOLD
OR MACHINE

BAYONET CAP

DRILL & TAP AS
REQ'D FOR ADAPTOR

STD. THREAD GAUGE

MACHINING DIMENSIONS FOR D-M-E

STANDARD BAYONET THERMOCOUPLES

ME-0708-PS-014-B TC/PS

Please read carefully before installing thermocouples

Note: Dimensions shown in Inches.

1.375

0.875

WIRING INFORMATION

A DIM.

HOLE DEPTH FOR ADAPTOR LENGTH

1.Thermocouple is J type Iron/Constantan supplied with

0.50 - 0.88

3/8-24 NF

2.00 - 2.38

THREAD

1/8-27 NPT

LENGTH

2. All thermocouples fit .438 DIA BAYONET Adaptor.

1.375

iron (magnetic).

09-08

1.50 - 1.88

SPECIFICATION

BA-1007

0.875

0.50 - 10.00

1/8-27 NPT

BA-4013

1.375

2.500

10.500 ADJ.

0.50 - 10.50

6.000

4.50 - 4.88

4.00 - 4.38

b. 1 T/C lead is BLACK and positive (+)

constantan (non-magnetic).

)

-

a. 1 T/C lead is WHITE and negative (

20 Gauge Stranded fiberglass insulated wire 52" long.

1.00 - 1.38

BA-4007

0.875

3/8-24 NF

3.500

BA-1013

L DIM.

THERMOCOUPLE

CATALOG

NUMBER

X DIM.