Ring gate nozzle series 625, D-m-e company, Installation data – DME 625 Series Ring Gate Nozzle User Manual
Page 2: Rg6/is
![background image](/manuals/410127/2/background.png)
WARNING
DANGER
be read before using this product. Failure to do so can result in serious
Failure to comply will result in serious injury or death:
ELECTRICAL HAZARDS
Improper voltages or grounding can result in electrical shock. Use only
with proper voltage and a proper earth ground.
To avoid electrical shock, do not operate product when wet.
Do not operate this equipment with covers or panels removed.
To avoid electrical shock, turn off main power disconnect and lockout /
tag out before servicing this device. Do not connect temperature sensors to
electrical power. It will damage the product and it could cause fire,
severe injuries or even death.
If green ground wire present wire must be connected to the ground.
Do not rebend rigid leads. Rebending leads might result in damage to circuit.
Product might absorb moisture when cool. Use low Voltage or power to drive
out residual moisture before applying full power. Failure to do so may cause
damage to this product.
Failure to comply can result in serious injury or death:
STORED ENERGY AND HIGH TEMPERATURE HAZARDS
This product maintains molten plastic at high pressure. Use caution when
operating and servicing the system.
Physical contact with molten plastic may result in severe burns. Proper
protective equipment, including eye protection, must be worn.
This product has heated surfaces. Use caution when operating and servicing
the system to avoid severe burns. Proper protective equipment should be worn.
IMPORTANT SAFETY INFORMATION
A hot-runner system includes electrical elements and may contain molten
plastic at elevated temperature and pressure.To avoid injury, exercise
caution by reading these instructions before servicing or operating the
system.
These instructions must be passed on to the end user where they should
injury or death.
29111 STEPHENSON HIGHWAY
MADISON HEIGHTS
MICHIGAN 48071 USA
US 800-656-6653
CANADA 800-387-6600
www.dme.net
INSTALLATION DATA
MACHINING &
RING GATE NOZZLE
SERIES 625
RG6/IS
ME-0741-PS-991-D
when removing tip counter-clockwise from the nozzle. If nozzle is still in the mold,
1. Apply an anti-seize compound on both the heater cover and tip threads.
2. Install the heater using a Square Coil Heater wrench (Wrench included
with replacement heater). After the heater is installed, it should cover the
entire length of the nozzle body - stretch the heater by hand if necessary.
3. Firmly screw the tip sub-assembly into the shank of the nozzle body.
Tighten and untighten two or three times making sure there is a good
contact between the tip and the shank. Torque to approximately 30 ft-lbs.
WIRING INFORMATION
Square Coil Heaters are supplied with 2" prestripped
36" long leads. Heaters are 240 VAC.
2 power leads are Multi Color.
1 ground lead is GREEN.
Thermocouple is "J" Type.
Thermocouple is supplied with 36" leads.
1 T/C lead is WHITE and negative (-)
constantan (non-magnetic).
1 T/C lead is BLACK and positive (+)
D-M-E COMPANY
iron (magnetic).
DISASSEMBLY PROCEDURE
1. Place the nozzle in a vice using "V" Block, then secure it firmly at the nozzle head.
2. For removal of tip from nozzle, a six point deep well socket is recommended. The
nozzle must be at processing temperature and the heater should be turned off
5. Cast-in heater may be removed if failure occurs and replaced with a Square Coil
Heater. Follow assembly procedures for Square Coil Heater.
08-08
replacement heater).
4. Remove the heater using a Square Coil Heater wrench (Wrench is included with
3. Tip must be cleaned of any material before reassembling.
the nozzle must be "keyed" to prevent wire damages.
OPERATING & SERVICING INSTRUCTIONS
FOR NOZZLE SERIES 250, 375, & 625
All interchangeable nozzles are similar, and differ only in size and material flow
capacity. The information found below applies to the nozzle series 250, 375 & 625.
OPERATING PROCEDURE
The nozzles are supplied with a Square (Flat) Coil equipped with a
Type J Thermocouple.
It is recommended to use a D-M-E closed loop Temperature Controller for optimum
Temperature Control.
When starting the nozzle, set the temperature to 10% voltage if using in open loop
manual type or to 200 F if using closed loop automatic type. In either case this
procedure will allow the heater to dissipate any moisture.
Make sure you maintain this start-up setting for 15 minutes.
Controller equipped with Step Smart ® , Smart Step ®
or other heater warm-up circuitry will change automatically.
It is essential to use controllers with the proper voltage and wattage capabilities.
The voltage and wattage of each heater is clearly marked on the heater tag.
Step Smart ®, Smart Start ® and DME ® are all registered trademarks
of DME Company.
ASSEMBLY PROCEDURE - "ALL PARTS MUST BE CLEAN"