5 full configuration, Vk-2 universal keyboard – Videoswitch VK-2 User Manual
Page 12

VK-2 Universal Keyboard
VK-2 Universal Keyboard User Manual
9
1.5 Full Configuration
1.5.1
Restore Factory Configuration
If you wish to return all settings to the factory defaults, follow this procedure:
• Power on the VK-2 while pressing the ALT key. Keep pressing the ALT key (for about 10 seconds)
until the word “
Fac” is displayed on the LED display.
• The VK-2 now has all factory settings restored.
1.5.2 Entering
Configuration
Mode
The VK-2 has a
Configuration Mode that is allows you to specify the dome protocols and change the
user password. To enter this mode, follow these steps:
• Holding
the
ALT key on, press the CONFIG key.
• The LED display will show “PSd”, indicating that a password must be entered.
• Enter the password using the number keys 1, 2, 3, 4, 5, 6, 7, 8, 9 and ZERO (the factory default
password is
123456). Note that only the last 3 digits are displayed.
• Press
the
YES key.
• If the password is rejected, the word “Rej” will be displayed;
• If the password is accepted, the display will flashing ”C1.1”. The VK-2 is now in Configuration
Mode. While is configuration mode, the display will always be flashing.
1.5.3
Selecting Dome Protocol for the “
DOMES-1” output
• Make sure that you are in Configuration Mode as detailed in section 1.5.2.
• Press
the
FUNCTION key.
• Press
the
NO key to select “DOME-1” output.
• Enter the protocol you require by pressing two number keys (refer to section 3). E.g. 1 followed by 2
would select Borsatec (protocol 12).
1.5.4
Selecting Dome Protocol for the “
DOMES-2” output
• Make sure that you are in Configuration Mode as detailed in section 1.5.2.
• Press
the
FUNCTION key.
• Press
the
YES key to select “DOME-2” output.
• Enter the protocol you require by pressing two number keys (refer to section 3). E.g. 1 followed by 2
would select Borsatec (protocol 12).
1.5.5
Assigning cameras to the “
DOMES-1” or “DOMES-2” outputs.
Following a factory reset, all cameras are allocated to the “
DOMES-1” output. If only one type of dome is
being used, this section can be skipped.
If two types of dome are to be controlled, all domes of one type should be connected to the “
DOMES-1”
output and all domes of the other type should be connected to the “
DOMES-2” output. Program the VK-2 to
tell it which domes are connected to which outputs as follows:
• Make sure that you are in Configuration Mode as detailed in section 1.5.2.
• Press
the
UNIT key and select the unit address (usually 1 if only one VDM being controlled)