3.7 Auto-Sequencing
3.7.1 Auto-Switch
Menu auto-switch is simple to set up and applies to the main monitor (HDI, VGA or BNC). Auto-
switching is enabled by setting a dwell time in this part of the menu:
Menu>Configuration>Live View>Dwell Time
3.7.2 Start/Stop
Auto-Switching
To start switching,:
Press
OK
To stop switching:
Right click mouse and select Stop-Auto-Switch
3.7.3 Auto-Sequencing
Each monitor can be set to auto-sequence using interface commands. For each monitor you can
specify which cameras you wish to be included in the sequence.
For example, to enable auto-sequencing for all cameras on monitor 1:
Press and hold LIVE key, enter6100, release LIVE key
For example, to enable auto-sequencing for all cameras on monitor 2:
Press and hold LIVE key, enter6200, release LIVE key
For example, to enable auto-sequencing for all cameras on monitor 3:
Press and hold LIVE key, enter6300, release LIVE key
For example, to enable auto-sequencing for all cameras on monitor 4:
Press and hold LIVE key, enter6400, release LIVE key
Note
:
See full listing of interface commands in section 16.
Before issuing any commands, issue an un-lock command as follows:
Press and hold LIVE key, enter 9001, release LIVE key
3.7.4 Auto-Sequencing across Cascaded Units
The master unit (DVR) can also be programmed to auto-sequence cameras across multiple cascaded
DVRs. For each monitor that you want to have auto-sequencing on, specify which cameras and which
units you want to be included in the sequence.