beautypg.com

Care of your product – CDN DTC450 - Digital Candy Thermometer EN User Manual

Page 2

background image

4. Use the heat shield when cooking with

temperatures over 300°F/148°C. Insert the stem

through the hole in the heat shield (open side

up), and slide it up to the bottom of the display.

CAUTION:

Initial positioning of the heat shield may

require more force. Be careful of the pointed tip.

5. With the loop of the attachment clip facing you,

insert the stem through the nearest portion of

both holes in the loop. Lock into the desired

position by pushing the stem away from you

and into the two locked positions. The second

locking position provides the most secure grip.

6. Push the clip down onto the side of the pot

(a straight sided pot works best) and position

it until the stem tip is just above the bottom of

the pot. Do not let the tip touch the bottom of

the pot.

Important: Keep stem away from direct heat of the

cooktop burner.

7. A 1-beep pre-alert sounds and the red LED

light flashes when the current temperature

reaches 3°F/2°C below the target temperature.

The alert changes to 2 beeps when the current

temperature reaches the target temperature.

It then changes to 3 beeps and the current

temperature flashes on the display when the

current temperature reaches 3°F/2°C above the

target temperature.

8. Press any button to stop the alert.
9. Remove the pot from the heat and the

thermometer from the side of the pot.

10. The DTC450 will turn off automatically when

the temperature is less than 104°F/40°C for

1 hour.

D. All-Purpose Temperature Stage

1. Press the + or – button to enter the desired

temperature. Press and hold for fast advance.

Care of Your Product

Avoid exposing your thermometer to extreme

temperatures, water or severe shock.

Avoid contact with any corrosive materials such as

perfume, alcohol or cleaning agent.

Wipe display clean with a damp cloth.

Clean stem, shield and clip with soap and water.

Note:

Clean the thermometer stem before each use.

Note for Induction Cooktops:

Sometimes, the induction

cooktop magnetic field may interfere with digital thermometers.

If there is interference, briefly turn off the induction cooktop to

get a digital thermometer reading or use a dial thermometer.

Important: DO NOT LEAVE IN HOT OVEN OR

MICROWAVE. DO NOT IMMERSE THE DISPLAY IN

WATER. HAND WASH AND DRY

OIL TEMPERATURE GUIDE

325–375°F/163-190°C is the normal desired

temperature for deep fry cooking.

Note:

When food is added to hot oil, the temperature of the oil

immediately drops at least 50°F/28°C. You will need to bring

the oil temperature back to the desired cooking temperature.

Frying at lower temperatures results in lighter color, less

flavor development and increased oil absorption.

DEEP FRY TEMPERATURE GUIDE

Deep Fry Lo . . . 325-340°F . . . . 163-170°C

Deep Fry Hi. . . . 340-365°F . . . . 170-185°C

Shrimp. . . . . . . . . . . . 350°F . . . . . . . 177°C

Chicken . . . . . . . . . . . 355°F . . . . . . . 180°C

Onions . . . . . . . . . . . . 370°F . . . . . . . 188°C

Fish . . . . . . . . . . . . . . 375°F . . . . . . . .191°C

Doughnuts/Fritters . 375°F . . . . . . . .191°C

French Fries . . . . . . .380°F . . . . . . . 193°C

CANDY TEMPERATURE GUIDE

Jelly . . . . . . . . . . . . . . 220°F . . . . . . . 104°C

Thread. . . . . . . . 230–234°F . . . .110–112°C

Soft Ball. . . . . . .234–240°F . . . .112–115°C

Firm Ball . . . . . .244–248°F . . . 118–120°C

Hard Ball. . . . . . 250–266°F . . . .121–130°C

Soft Crack . . . . .270–290°F . . . .132–143°C

Hard Crack . . . . 300–310°F . . . 149–154°C

Caramelize . . . . 316–338°F . . . .158–170°C

HIGH ALTITUDE ADJUSTMENT

FOR CANDY-MAKING

STAGE

2,000 feet 5,000 feet 7,500 feet

Soft Ball

230–236°F 224–230°F 219–225°F

Firm Ball

238–244°F 232–238°F 227–233°F

Hard Ball

246–264°F 240–258°F 235–253°F

Soft Crack 266–286°F 260–286°F 255–275°F

Hard Crack 296–306°F 290–300°F 285–295°F

CAUTION:

Avoid keeping the thermometer too close to objects

that continuously generate high heat for long periods (i.e., hot

plate). This can cause the thermometer to overheat.

CE Note: This device could be sensitive to electrostatic

discharge. If electrostatic discharge or malfunctioning occurs,

please re-install the battery to reset this unit.