3.1 POWER WIRING

3.2 CONTROL INPUT WIRING

The PAXLC provides a number of control inputs, including Store, Reset,

Inhibit and Up/Down control. These inputs are active low (connected to
common), so the external switching device should be connected between the
control input and common terminals.

Up/Down - This input determines the direction of the count. Unconnected,

the meter will count up. When input is pulled low, the meter will count down.

Reset - When this input is pulled low, the meter will reset to zero. If the input

remains low or connected to common, the meter will be held in the reset mode,
and not able to count.

Inhibit - When low, this input will prevent the meter from counting. If the

input remains low or connected to the common, the meter will not be able to
count.

Store - A low will stop the display from updating. It will freeze the display

as long as the input is held low. Once released the display will update to the
current count display.

1

2

AC

AC

AC Power

Terminal 1: VAC

Terminal 2: VAC

3

4

DC OUT/IN

COMM

+

-

DC Power

Terminal 3: +VDC

Terminal 4: COMM

COMM

6

STORE

INHIBIT

RST

UP/ DOWN

7

8

10

9

3.3 INPUT WIRING

4

3

5

2.2K

COMM

1

ON

2

4

3

INPUT

*

DC OUT/IN

NPN O.C.

3

4

5

COMM

ON

4

1 2 3

INPUT

*

DC OUT/IN

PNP O.C.

3

4

5

COMM

3

1

ON

2

4

INPUT

*

DC OUT/IN

4

3

5

+5V

COMM

DIODE

COMM

3

1

ON

2

4

INPUT

*

DC OUT/IN

3

4

5

COMM

1

ON

3

2

4

INPUT

*

DC OUT/IN

3

4

5

COMM

2

ON

1

3 4

INPUT

*

DC OUT/IN

3

4

5

COMM

2

ON

1

3 4

INPUT

*

DC OUT/IN

Current Sourcing Output

Interfacing With TTL

Two Wire Proximity, Current Source

Current Sinking Output

Switch or Isolated Transistor; Current Sink

Switch or Isolated Transistor; Current Source

Emitter Follower; Current Source

*Switch position is application dependent.

This manual is related to the following products: