Rs232 ports, Examples of rs485 2-wire connections, Dh485 communications – Red Lion G306 5.7" Ultra-STN Color Touch Panel User Manual
Page 5: G3 to modular controller (cblrlc05)

RS422/485 COMMS PORT
The G306A has one RS422/485 port. This port can be configured to act as
either RS422 or RS485.
Note: All Red Lion devices connect A to A and B to B, except for Paradigm
devices. Refer to www.redlion.net for additional information.
5
RS232 PORTS
The G306A has two RS232 ports. There is the PGM port and the COMMS
port. Although only one of these ports can be used for programming, both ports
can be used for communications with a PLC.
The RS232 ports can be used for either master or slave protocols with any
G306A configuration.
Examples of RS232 communications could involve another Red Lion product
or a PC. By using a cable with RJ12 ends on it, and a twist in the cable, RS232
communications with another G3 product or the Modular Controller can be
established. Red Lion part numbers for cables with a twist in them are
CBLPROG0
1
, CBLRLC01
2
, or CBLRC02
3
.
Connections
G3: RJ12
Name
PC: DB9
Name
4
COMM
1
DCD
5
Tx
2
Rx
2
Rx
3
Tx
N/C
4
DTR
3
COM
5
GND
N/C
6
DSR
1
CTS
7
RTS
6
RTS
8
CTS
N/C
9
RI
OFF 4 WIRE/ ON 2 WIRE
OFF 4 WIRE/ ON 2 WIRE
*
**
*
*
*
* * *
*
9
PULL UP
PULL DOWN
115200 BAUD
57600 BAUD
38400 BAUD
19200 BAUD
9600 BAU
D
2
1
5
3
4
7
8
6
OFF DCE/ ON DT
E
OFF DCE/ ON DT
E
OFF DTE/ ON DC
E
OFF 422/ ON 48
5
OFF 422/ ON 48
5
OFF DTE/ ON DC
E
120 Ω TERMINATIO
N
5
NC
10
1
3
2
4
6
7
ON
ON
CBLPROG0
ICM5
CONNECTING A G306A OPERATOR
INTERFACE TO AN ICM5
*
Application Dependent
ICM5 DIP Switch Settings
Examples of RS485 2-Wire Connections
G3 to Red Lion RJ11 (CBLRLC00)
DLC, IAMS, ITMS, PAXCDC4C
A+
4
TxA
2
B-
5
TxB
1
COM
3
COM
6
TxEN
2
TxEN
5
Name
RLC: RJ11
Name
G3: RJ45
Connections
G3 to Modular Controller (CBLRLC05)
TxA
8
TxA
8
TxB
7
TxB
7
COM
6
COM
6
TxEN
5
TxEN
5
RxA
TxA
3,2
2,3
RxA
TxA
3,2
2,3
RxB
4,1
RxB
4,1
TxB
1,4
TxB
1,4
Name
Modular Controller
Name
G3
Connections
1
CBLPROG0 can also be used to communicate with either a PC or an ICM5.
2
DB9 adapter not included, 1 foot long.
3
DB9 adapter not included, 10 feet long.
DH485 COMMUNICATIONS
The G306A’s RS422/485 COMMS port can also be used for Allen Bradley
DH485 communications.
WARNING: DO NOT use a standard DH485 cable to connect this port to Allen
Bradley equipment. A cable and wiring diagram are available from Red Lion.
G3 to AB SLC 500 (CBLAB003)
24V
-
TxA
3, 8
COMM
-
TxB
4, 7
SHIELD
4
COMM
6
TxEN
5
TxEN
5
COMM
-
RxB
4, 7
24V
-
RxA
3, 8
B
2
TxA
2
A
1
TxB
1
Name
RJ45: A-B
Name
RJ45: RLC
Connections
TX
5V
8
1
7
2
TxB
TxA
130K
130K
5
TxEN (OC)
RX
130K
5V
130K
RxB
4
RxA
3
GND
6
TxEN (OC)
TX/RX
130K
5
TxA
2
8
130K
5V
7
1
TxB
6
GND
RS422/485 4-WIRE
CONNECTIONS
RS485 2-WIRE
CONNECTIONS
G3 RS232 to a PC