Chapter 5 ____________________________________________ Humidity measurements in concrete

VAISALA __________________________________________________________________________

15

Maximum humidity levels for coating

SisäRYL 2000 Code of Building Practice (RT 14-10668, 2000, ISBN 951-682-506-0)
recommends the following maximum humidity levels (at +20

°C) for coating of various

materials :

Wooden floor coverings

Maximum

RH (%)

Coating

60

1

Wooden parquet boards without moisture barrier (plastic film)
between wood and concrete.

80

1

Enlaid wooden floor coverings.
Floating wooden floor coverings with moisture barrier (plastic
film) between wood and concrete.

1

SisäRYL 2000 Code of Building practice, RT 14-10668, 2000, ISBN 951-682-506-0, page 332.

Other materials

Maximum

RH (%)

Coating

85

1

Plastic floor coverings with fibre felt base or cellular plastic
base
Rubber floor coverings
Cork tiles with moisture barrier (plastic film)
Textile floor coverings with rubber, PVC or latex base
Natural fibre textile floor coverings without base

90

1

Plastic tiles
Plastic floor coverings without felt or cellular plastic base
Linoleum (Cork)
Man-made fibre textile floor coverings without base structure

97

Epoxy mass
Acrylic mass
Polyester plastic mass

1

SisäRYL 2000 Code of Building practice, RT 14-10668, 2000, ISBN 951-682-506-0, page 318.