2.2. Installing the CM375 Mast with the Inversion System
This procedure is for customers who are installing the CM375 30-foot mast at the same time as their inversion system.
Use Procedure 1 (instead of this procedure) if your CM375 mast has already been installed. The table below is a list of
hand tools necessary for installing the CM375 mast with the inversion system.
Hand Tool List
½ inch Wrench
Compass
#2 Phillips Screwdriver
Rubber Mallet
Small Wire Cutters
Guy-wire Tension Tool
Tape Measure (25 ft)
Post Level
The compass, guy-wire tension tool, and post level are included in the Tensioning Kit which can be purchased
separately from WeatherHawk.
The following tables list the equipment that is included with the WeatherHawk Inversion System. To ensure that all
equipment is present, and inventory should be conducted before beginning installation.
Inversion System Common Components
Equipment Description
Part Number
Quantity
Temperature Probe, Top
21414
1
Temperature/RH Probe, Bottom
21415
1
6-Plate Gill Solar Radiation Shield
4020
2
Lead Acid Battery, 12 Volt, 2.9 AHr
18860
1
Wind Sensor Set w/Mounting Hardware
21413
1
Cable Tie, Black, UV Resistant
17592
12
Direct Connect System Specific Components
Equipment Description
Part #
Qty
Enclosure Assembly – 232
21379
1
RS – 232 Optical Isolator, 9 – pin
21429
1
RS – 232 Optical Isolator
Power Supply
21435
1
RS – 232 Data Cable
10873
1
Wireless System Specific Components
Equipment Description
Part #
Qty
Enclosure Assembly – 916
21380
1
900MHz Spread Spectrum
Radio
18102
1
900MHz Dipole Antenna
15970
1
Radio Power Adapter
15966
1
CM375 Mast Assembly
Description
Qty
Description
Qty
Baseplate Assembly
1
Grounding cable w/hardware
1
Baseplate Stakes
4
Duckbilled anchor driver
1
Mast Extensions
5
Duckbilled anchor w/cables
3
Mast Extension Couplers
3
Guy wire set, short
1
Mast Hardware
8 sets
Guy wire set, long
1
Lightning Rod with bracket
1
Turnbuckles
6
Cross-arm w/mounting hardware
1
Ground Rod
1
The top temperature probe and bottom temperature/RH probe should already be housed in the 6-plate solar radiation
shield. The mast extension couplers should already be installed on the proper mast extensions.