Installation
Page 2-10
Setting up for
Management
To use the IntraSwitch 5324 as a managed switch, it must be 
configured with an IP address. This can be accomplished in 
one of two ways: 
❏
automatically using BootP (default)
❏
manually via the Console port
BootP
Configuration
The IntraSwitch is shipped with BootP/TFTP support. BootP 
allows the switch to be automatically configured with an IP 
address when the switch is connected to the network and is 
powered on, if your network contains a BootP server 
configured with available IP addresses.
▲
Important: BootP configuration only works if 
the switch does not have an IP address assigned 
to it. By default, the IntraSwitch is shipped 
without an assigned IP address.
1
Make sure your network has a BootP server con-
figured with a valid IP address entry for the 
IntraSwitch 5324.
2
When the IntraSwitch is connected to the net-
work and is powered on, it automatically trans-
mits a BootP request across the network (up to 
5 times) until it receives a valid IP address from 
the BootP server.
3
After an IP address is received, the switch can 
be managed. 
See Chapter 4 for information on connecting to 
the switch for management.
To verify that the switch received an IP address, 
use a tool such as Ping
1
to try and access the
IntraSwitch; if you can access the IntraSwitch, it 
is properly configured with an IP address. 
1. Ping (an acronym for packet internet groper) is an application that can be used to
test whether a remote device is properly connected to a network.