Appendix A: Switching Data Loggers
To switch out a USB data logger for a serial data logger:
1. If you are using a console, enter Setup Mode (press and hold DONE and -).
2. Power down the console or Weather Envoy (batteries and AC).
3. Unplug the USB data logger; plug in the serial data logger.
4. Repower the console or Envoy.
5. Check the time and adjust if necessary. Use the console key pad or
WeatherLink software (Envoy or console) to set the correct time.
Tip:
To change the time on a console or Envoy, see your instruction manual.
Contacting Davis Technical Support
For questions about installing or operating your Vantage Connect Retrofit Kit,
please contact Davis Technical Support. We’ll be glad to help.
Specifications
G e n e r a l :
Cellular Bands . . . . . . . . . . . . . . . . . . . 850, 900, 1800, 1900 MHz
Operating Temperature. . . . . . . . . . . . . -22° to +149°F (-30° to +65°C)
Storage Temperature . . . . . . . . . . . . . -40° to +185°F (-40° to +85°C)
Current Draw . . . . . . . . . . . . . . . . . . . . 25mA typical, 1A peak
GPRS class 10: 146mA typical
Transmitter Power . . . . . . . . . . . . . . . . 2W @ 850/900 MHz (Class 4)
1W @ 1800/1900 MHZ (Class 1)
AC Power Adapter . . . . . . . . . . . . . . . . 12 VDC, 1.5A peak power 2.1mm
barrel jack
Housing Material . . . . . . . . . . . . . . . . . Rugged ABS Plastic
Dimensions (width x length x height) . . 2.6" x 3.75" x 1.2"
(66mm x 95.25mm x 30.84mm)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . 0.28 lb (127 g)
Certifications: . . . . . . . . . . . . . . . . . . . . . . FCC PTCRB CE Carrier