Installing Surge Protectors and Ground Wires

Page 5

Installing Ground Lug and Ground Jumpers

1. Attach the ground lug to the bottom of the shelter using a #10-32 x 1” (25 mm) screw,

washer, lock washer, and hex nut as shown below.

A

TTACHING

G

ROUND

L

UG

2. Slide the spade lug on the end of one ground jumper over the #10-32 screw joining

the lowest pair of surge protectors. Secure in place using a #10 washer, lock washer,
and hex nut.

Repeat on the other side using the second ground jumper.

3. Slide the spade lug on each ground jumper over the end of the #10 screw holding the

ground lug in place. Secure the ground jumper using a #10 washer, lock washer, and
hex nut as shown below.

C

ONNECTING

G

ROUND

J

UMPERS

TO

G

ROUND

L

UG