Installing in Multi-Purpose Shelter
Page 3
I
NSTALLING
IN
M
ULTI
-P
URPOSE
S
HELTER
Follow the instructions below to install the Radio Surge Protector (referred to
as the protector) in the Multi-Purpose Shelter (MPS).
1. Using a 7/32" drill bit, drill a hole in the MPS in the location shown below.
2. Install the protector and ground lug as shown below, using the #10-32 x 1" (25 mm)
machine screw, spacer, and the tooth lock washers and #10 hex nut from the mount-
ing hardware kit supplied with the protector.
3. Insert one end of the ground wire into the ground lug and tighten.
The use of a heavier ground wire or strap is recommended if nearby light-
ning strikes are likely.
4. Attach the other end of the ground wire to a suitable earth ground.
5. Connect the cable coming from the antenna to the ANTENNA side of the protector and
the cable from the modem to the EQUIPMENT side of the protector.
Consult the manual supplied with your installation kit for exact cabling
instructions.
Machine
Screw
Lock
Washer
Lock
Washer
Hex Nut
Radio
Surge
Protector
Ground
Lug
Ground
Wire
Aluminum
Spacer
User-Drilled Hole
7/32" Diameter
(.218", 5.5 mm)
5.5"
(140 mm)
1.3"