beautypg.com

Mounting on a wood surface, Place the shield onto the body as shown below, Placing shield onto body – DAVIS Sensor - UV for GroWeather or EnviroMonitor User Manual

Page 10: Uv sensor mounting holes template

background image

Page 10

UV Sensor

Mounting on a Wood Surface

Follow the instructions below to mount the sensor on a wood surface.

1. Using the template printed at the bottom of this page, mark the location of the neces-

sary pilot holes.

2. Using a drill with a #36 (2.7 mm) drill bit, drill pilot hole in the marked locations. If

necessary, bore a hole through the mounting surface using a 7/8" (22 mm) drill bit so
the bottom of the sensor can sit inside of it and the sensor cable can run to the other
side.

3. Route the sensor cable through the hole in the wood if desired.

4. Place the shield onto the body as shown below.

P

LACING

S

HIELD

ONTO

B

ODY

5. Place a flat washer over the end of each screw and insert it into the body.

6. Place a spring over the end of each screw and hold the springs in place using a #4

screw retainer.

Use the template below to center-punch or mark pilot holes before drilling.

UV S

ENSOR

M

OUNTING

H

OLES

T

EMPLATE