beautypg.com

5 digital communicator and annunciators, 1 adt-udact digital alarm communicator/transmitter, 2 adt-acm-8r relay control module – ADT Security Services Unimode 9600 User Manual

Page 35: 2swlrqdo 0rgxohv dqg 'hylfhv ,qvwdoodwlrq, Event, Hold 2 sec, 8qlprgh 31

background image

2SWLRQDO 0RGXOHV DQG 'HYLFHV

,QVWDOODWLRQ

8QLPRGH 31 &

2.6.5 Digital Communicator and Annunciators

2.6.5.1 ADT-UDACT Digital Alarm Communicator/Transmitter

7KH $'78'$&7 WUDQVPLWV V\VWHP VWDWXV WR 8/ OLVWHG &HQWUDO 6WDWLRQ UHFHLYHUV YLD

WKH SXEOLF VZLWFKHG WHOHSKRQH QHWZRUN ,W LV FDSDEOH RI UHSRUWLQJ XS WR VRIWZDUH

]RQHV RU XS WR DGGUHVVDEOH SRLQWV 7KH $'78'$&7 FDQ EH PRXQWHG UHPRWHO\ LQ

D 8%6) RU $'7$%65) HQFORVXUH RU LQ WKH SDQHO FDELQHW XVLQJ WKH 31 %5.7

8QLYHUVDO %UDFNHW UHIHU WR $'78'$&7 0DQXDO 7KH 8QLPRGH LV

FRPSDWLEOH ZLWK $'78'$&7 VRIWZDUH 8'$&7 DQG DERYH
3URJUDPPLQJ

7KH 8QLPRGH PXVW EH SURJUDPPHG WR RSHUDWH ZLWK WKH $'78'$&7 5HIHU WR

$QQXQFLDWRUV8'$&7 RQ SDJH IRU FRQWURO SDQHO SURJUDPPLQJ LQIRUPDWLRQ

2.6.5.2 ADT-ACM-8R Relay Control Module

7KH $'7$&05 PRGXOH SURYLGHV HLJKW )RUP& UHOD\V ZLWK FRQWDFWV UDWHG IRU

DPSV :KHQ LQVWDOOHG ZLWK DQ 8QLPRGH )$&3 WKH $'7$&05 PRGXOHV

SURYLGH UHOD\ DFWLYDWLRQ IRU HDFK RI WKH SRVVLEOH )$&3 ]RQHV SOXV VSHFLDO IXQFWLRQV

2SWLRQV H[LVW WR DOORZ IRU DODUP RQO\ RU DODUP DQG WURXEOH DFWLYDWLRQ SHU ]RQH 2XWSXW

DFWLYDWLRQ IRU JHQHUDO DODUP JHQHUDO WURXEOH JHQHUDO VXSHUYLVRU\ 1$& IDXOW $& IDLO

ZDONWHVW VWDUW DQG EDWWHU\ WURXEOH DUH DOVR DYDLODEOH 7KH $'7$&05 FDQ EH

PRXQWHG UHPRWHO\ LQ DQ $'7$%65) DQQXQFLDWRU VXUIDFHPRXQW EDFNER[ RU LQ WKH

SDQHO FDELQHW XVLQJ WKH 31 %5.7 8QLYHUVDO %UDFNHW 5HIHU WR WKH $'7$&0

5 PDQXDO IRU LQIRUPDWLRQ RQ VHWWLQJ PRGXOH VZLWFKHV IRU DGGUHVVLQJ DQG UHOD\

IXQFWLRQV

2.6.5.3 BRKT-9600 Universal Bracket Installation

7KH RSWLRQDO %5.7 8QLYHUVDO %UDFNHW FDQ EH XVHG WR PRXQW VSHFLILF PRGXOHV

LQVLGH WKH 8QLPRGH FDELQHW 7KH %5.7 PRXQWV WR WZR VWXGV ORFDWHG LQ WKH

ORZHU ULJKW FRUQHU RI WKH FRQWURO SDQHO FDELQHW DV LOOXVWUDWHG EHORZ ,W LV VHFXUHG WR WKH

3(0 VWXGV RQ WKH EDFN ZDOO RI WKH FDELQHW ZLWK WZR VXSSOLHG KH[ QXWV
,03257$17 :KHQ WKH %5.7 LV LQVWDOOHG WKH 8QLPRGH FDELQHW FDQ

KROG D PD[LPXP RI WZR $PS +RXU EDWWHULHV ZLWK WKH RULHQWDWLRQ LOOXVWUDWHG EHORZ

Reference

Manual

See Page

Reference

Manual

+BATTERY-

LCD DISPLAY

KEYPAD I/F

1

2

3

OPT DACT

HOT

CB1

J3

J12

J2

TB1

TB2

TB3

JP3

JP2

JP8

JP4

JP7

JP5

JP6

J17

J16

J6

J8

J7

JP10

JP11

CUT TO

DISABLE
LOCAL

CHARGER

DISABLE

GND
FLT

CUT TO

MONITOR 4XTM

OPT SLC

4XTM OPT BD

TB4

TB5

TB6

TB7

TB8

NEUT EARTH

1

4

*

2

5

0

3

6

#

1

st

EVENT

ABC

DEF

GHI

JKL

MNO

PRS

TUV

WXY

QZ

-/.

CLR

7

8

9

ESC

ENTER

RECALL

ACK/STEP

ALARM

SILENCE

DRILL

HOLD 2 SEC

RESET

MODE

MAINTENANCE

GROUND

BATTERY

DISABLED

ALARM

SILENCED

TROUBLE

SUPERVISORY

FIRE ALARM

AC POWER

Figure 2.13 BRKT-9600 Bracket Installation

Mount BRKT-9600 to PEM
studs on back of cabinet
using supplied hex nuts.

Unimode 9600 Cabinet

96br

km

nt.c

dr