beautypg.com

Combo-forced-mode, Shutdown, Combo-forced-mode 4-128 shutdown 4-128 – Accton Technology ES4512C User Manual

Page 320: Shutdown co, Shutdown (4-130)

background image

Command Line Interface

4-130

4

Example

The following example enables flow control on port 5.

Related Commands

negotiation (4-127)
capabilities (flowcontrol, symmetric) (4-128)

combo-forced-mode

This command forces the port type selected for combination ports 21-24/45-48. Use
the no form to restore the default mode.

Syntax

combo-forced-mode mode
no combo-forced-mode

mode

- copper-forced - Always uses the built-in RJ-45 port.
- copper-preferred-auto - Uses the built-in RJ-45 port if both combination

types are functioning and the RJ-45 port has a valid link.

- sfp-forced - Always uses the SFP port (even if module not installed).
- sfp-preferred-auto - Uses SFP port if both combination types are

functioning and the SFP port has a valid link.

Default Setting

sfp-preferred-auto

Command Mode

Interface Configuration (Ethernet)

Example

This forces the switch to use the built-in RJ-45 port for the combination port 48.

shutdown

This command disables an interface. To restart a disabled interface, use the no
form.

Syntax

[no] shutdown

Console(config)#interface ethernet 1/5
Console(config-if)#flowcontrol
Console(config-if)#no negotiation
Console(config-if)#

Console(config)#interface ethernet 1/48
Console(config-if)#combo-forced-mode copper-forced
Console(config-if)#