2-30

SECTION III

ALIGNMENT / ZEROING

2.16 ALIGNMENT / ZEROING PROCEDURES

2.16.1 Clip-On

.

WARNING

..

Activating HAND mode when the CNVD-T3 is
being used in-line with a magnified day optic may
induce an error in the aiming function of the sight.


When being used in-line with an optical sight, the CNVD-T3
should be placed in ZOOM 1X, the reticle should be turned
off, and zeroing procedures associated with the primary sight
should be used. Ensure that the CLIPON setting is selected
via the CNVD-T3 Main Menu as described in section
2.13.10. Placing the CNVD-T3 in front of an already zeroed
optic / weapon combination does not necessitate rezeroing.

2.16.2 Stand-Alone

. Each click of the CNVD-T3 reticle

moves the shot group about 0.6cm at 25m (when in ZOOM
1X). Other click equivalents are provided in Table 2-2.
Changing the position of the reticle corresponds to a
subsequent change in shot group movement (i.e., the UP
button will move the strike of the round up).

Table 2-2 Reticle Adjustments

Single Click Equivalents

10m

25m

100m

150m

300m

ZOOM 1X

0.3cm

0.6cm

2.5cm

3.8cm

7.5cm

ZOOM 2X

0.1cm

0.3cm

1.3cm

1.9cm

3.4cm