beautypg.com

American Fibertek CX-6p-PoE User Manual

Page 16

background image

16

Factory default IP

The CX-6p-PoE is factory programmed with the following default network settings:

IP address

192.168.0.246

Netmask

255.255.255.0

Gateway

192.168.0.143

DNS

None programmed


If the CX-6p-PoE has not had its IP address changed by the user it will be possible to
connect to it at this network address. If you do not know the IP address of the unit, you
can reset the unit back to factory defaults and then connect at the default address.


Reset sequence

If the IP address or username and password to log in are not know, it will be necessary
to reset the CX-6p-PoE to factory defaults in order to access the administration web
interface. The reset procedure will set all unit settings to their factory defaults.

To reset the CX-6p-PoE perform the following steps:

Disconnect power from the CX-6p-PoE

With a paperclip or other small object, press and hold the reset button recessed

in the rear of the unit

Connect power to the CX-6p-PoE

Wait ten seconds

Release the reset button


The CX-6p-PoE will now be reset to factory default configuration. This will reset all user-
configurable settings, including network address, username and password, and all
contact and serial interface settings.