beautypg.com

Scale factor, Press contrler settings key. set the following, Note: the pf does not support the planter channel – Ag Leader PFadvantage Flexicoil Flex Control Quick Reference Sheets User Manual

Page 3: How to change a setting

background image

PF3000 and PF3000 Pro – Quick Reference Setup Instructions for Flexi-coil Flexcontrol – March 2002

Revision 2

3 of 4

P.N. 2002831-24

Note: These instructions pertain to PF firmware versions 4.00 or
higher.

Settings for Flexi-coil Flexcontrol controller

1.

Press SETUP key. Press APP RATE CONFIG key. Press CREATE
NEW key. Set the following:
Controller Make: Set to FLEXICOIL.
Controller Model:
Set to FLEXCONTROL.
Product:
Press EDIT key. You can select an existing product and press
ACCEPT key or create a new product by pressing CREATE NEW key.
Press EDIT NAME key and enter name of product. Use Left or Right
Arrow keys to select a character. Use Up or Down Arrow key to change
the character. Set every character and press ACCEPT key twice.
Units: Set to Units/Acre of application.
Ground Speed Sensor: Set to SERIAL or GPS. Serial is recommended.
App Distance From GPS: Set to distance between where product exits
applicator and position of GPS antenna on vehicle. Example: If spray
boom is 20 feet behind GPS antenna set to 20 ft back.
Full Swath: Ignore setting. Swath comes from serial port of controller.
Tgt Units:Contrler Units: Normally set to 1:1.0000. This ratio is used to
convert the units in a target file (.tgt) to the units of application.
Example: Tgt file in pints/ac of Treflan, controller applies gallons/ac. If
tank mix is 1 pint of Treflan / 10 gallon water, then set to 1:10.0000.
Target Rate Increment: Determines increment value by which you can
change the manual target rate with each press of Up or Down arrow keys.
Actual Rate Scale Factor: Use chart below for setting.

Avg. Speed

Swath

Application Rate between

Scale Factor

0-25 mph

0-80 ft

0-10 units/ac

1.000

0-10 mph

0-80 ft

11-100 units/ac

1.000

11-15 mph

0-50 ft

11-100 units/ac

1.000

11-15 mph

51-80 ft

11-100 units/ac

0.100

16-25 mph

0-80 ft

11-100 units/ac

0.100

0-25 mph

0-80 ft

101-500 units/ac

0.100

0-10 mph

0-80 ft

501-1000 units/ac

0.100

11-15 mph

0-50 ft

501-1000 units/ac

0.100

11-15 mph

51-80 ft

501-1000 units/ac

0.010

16-25 mph

0-80 ft

501-1000 units/ac

0.010

0-25 mph

0-80 ft

1001+ units/ac

0.010


When the data is mapped, the rate will be 1/10

th

of the real rate when the

Actual Rate Scale Factor is 0.100. It will be 1/100

th

of the real rate when

the Actual Rate Scale Facotr is 0.010. The rate actually applied and rate
that appears on Pro is unaffected by this setting.

2

Press CONTRLER SETTINGS key. Set the following:
Controller Channel: Set to channel of Flexi-coil to record or control rate.

Note: The PF does not support the Planter channel.

3

Press EXIT key to return to screen with ADVANCED SETTINGS key on
bottom. Press the ADVANCED SETTINGS key.
Target Rate Outside Field: This only pertains to using a target file.

Set to ZERO if want rate outside field to be zero.
Set to USE LAST if want rate to be the last rate used at the time the

vehicle is detected outside the field. This is useful when experiencing
problems with the vehicle being falsely detected outside of the field
during the outside pass.

Set to TGT DEFAULT if want rate outside field to be the default rate

stored in the target rate file.

Controller Time Delay: Set to 3 seconds. This is delay of controller to
change application equipment to new rate + 2 seconds.
Actual Rate Units: Ignore this setting.
Log Actual Rate: YES to log actual rate to card. Set to NO, otherwise.

4

Exit back to main screen.
a)Press FIELD key twice.
b)Select appropriate field and press VIEW CONFIG key.
c)Select appropriate product/controller configuration and press ACTIVE

ON/OFF key to check it as active.(All other configs must be unchecked
first).

d)If you will be using a target file, press EDIT TGT FILE key, otherwise

press EXIT key and skip to step f.

e)Select target file. Press VIEW INFO key to ensure it is the correct one.

After exiting view info screen, press ACCEPT key. Press EXIT key.

f)Press ACCEPT key to accept field.

Note: The cable part number 14927 is required from Flexi-coil. It plugs
directly into Port3 of the PF. No settings need to be made on the Flexcontrol
to enable it to communicate with the PF3000.

How to change a setting

Press the EDIT key and use the Up or Down Arrow keys to change the setting.
For most settings, you can set each digit by pressing the Left or Right Arrow
key to select the digit. Use the Up or Down Arrow keys to set the digit.

This manual is related to the following products: