LED descriptions

Rear panel LEDs

Controller enclosure—rear panel layout

The diagram and table below display and identify important component items comprising the rear panel

layout of the MSA 2040 controller enclosure (MSA 2040 SAN is shown in the example). Diagrams and

tables on the following pages further describe rear panel LED behavior for component field-replaceable

units.

Figure 34 MSA 2040 SAN Array: rear panel

A controller enclosure accommodates two power supply FRUs of the same type—either both AC or both

DC—within the two power supply slots (see two instances of callout 1 above). The controller enclosure

accommodates two controller module FRUs of the same type within the I/O module slots (see callouts 2

and 3 above).

IMPORTANT:

If the MSA 2040 controller enclosure is configured with a single controller module, the

controller module must be installed in the upper slot (see callout 2 above), and an I/O module blank must

be installed in the lower slot (see callout 3 above). This configuration is required to allow sufficient air flow

through the enclosure during operation.

The diagrams with tables that immediately follow provide descriptions of the different controller modules

and power supply modules that can be installed into the rear panel of an MSA 2040 controller enclosure.

Showing controller modules and power supply modules separately from the enclosure provides improved

clarity in identifying the component items called out in the diagrams and described in the tables.
Descriptions are also provided for optional drive enclosures supported by MSA 2040 controller enclosures

for expanding storage capacity.

1

AC Power supplies [see

Figure 38

(page 80)]

2

Controller module A [see

Figure 35

(page 77)]

3

Controller module B [see

Figure 35

(page 77)]

4

Host ports: used for host connection or replication

5

CLI port (USB - Type B)

6

Service port 2 (used by service personnel only)

7

Reserved for future use

8

Network port

9

Service port 1 (used by service personnel only)

10

Disabled button (used by engineering only)

(Stickers shown covering the openings)

11

SAS expansion port

12

DC Power supply (2) — (DC model only)

13

DC Power switch [see

Figure 38

(page 80)]

CACHE

LINK

ACT

6Gb/s

CACHE

LINK

ACT

6Gb/s

CLI

CLI

PORT 3

PORT 4

SERVICE−1

SERVICE−2

PORT 1

PORT 2

CLI

CLI

PORT 3

PORT 4

SERVICE−1

SERVICE−2

PORT 1

PORT 2

1

4

8

q

1

=

6

9

w

-

5

7

2

3

MSA 2040 controller enclosure
(rear panel locator illustration)