beautypg.com

HP MSA 2040 SAN Storage User Manual

Page 59

background image

Isolating a host-side connection fault

59

3.

Check the Cache Status LED to verify that the controller cached data is flushed to the disk drives.
• Solid – Cache contains data yet to be written to the disk.
• Blinking – Cache data is being written to CompactFlash.
• Flashing at 1/10 second on and 9/10 second off – Cache is being refreshed by the supercapacitor.
• Off – Cache is clean (no unwritten data).

4.

Remove the SFP and host cable and inspect for damage.

5.

Reseat the SFP and host cable.
Is the host link status/link activity LED on?
• Yes – Monitor the status to ensure that there is no intermittent error present. If the fault occurs again,

clean the connections to ensure that a dirty connector is not interfering with the data path.

• No – Proceed to the next step.

6.

Move the SFP and host cable to a port with a known good link status.
This step isolates the problem to the external data path (SFP, host cable, and host-side devices) or to the

controller module port.
Is the host link status/link activity LED on?
• Yes – You now know that the SFP, host cable, and host-side devices are functioning properly. Return

the SFP and cable to the original port. If the link status/link activity LED remains off, you have

isolated the fault to the controller module port. Replace the controller module.

• No – Proceed to the next step.

7.

Swap the SFP with the known good one.
Is the host link status/link activity LED on?
• Yes – You have isolated the fault to the SFP. Replace the SFP.
• No – Proceed to the next step.

8.

Re-insert the original SFP and swap the cable with a known good one.
Is the host link status/link activity LED on?
• Yes – You have isolated the fault to the cable. Replace the cable.
• No – Proceed to the next step.

9.

Verify that the switch, if any, is operating properly. If possible, test with another port.

10.

Verify that the HBA is fully seated, and that the PCI slot is powered on and operational.

11.

Replace the HBA with a known good HBA, or move the host side cable and SFP to a known good

HBA.
Is the host link status/link activity LED on?
• Yes – You have isolated the fault to the HBA. Replace the HBA.
• No – It is likely that the controller module needs to be replaced.

12.

Move the cable and SFP back to its original port.
Is the host link status/link activity LED on?
• No – The controller module port has failed. Replace the controller module.
• Yes – Monitor the connection for a period of time. It may be an intermittent problem, which can

occur with damaged SFPs, cables, and HBAs.

Host-side connection troubleshooting featuring SAS host ports

The procedure below applies to MSA 2040 SAS controller enclosures employing 12 Gb SFF-8644

connectors in the HD mini-SAS host ports used for I/O.

1.

Halt all I/O to the storage system as described in

"Stopping I/O" (page 53)

.

2.

Check the host activity LED.
If there is activity, halt all applications that access the storage system.

3.

Check the Cache Status LED to verify that the controller cached data is flushed to the disk drives.
• Solid – Cache contains data yet to be written to the disk.
• Blinking – Cache data is being written to CompactFlash.