beautypg.com

Npars and blade link domain, Npars and vc profiles, Debugging bl8x0c i4 npars problems – HP Integrity BL870c Server-Blade User Manual

Page 43

background image

consisting of N blades is treated just like a server consisting of N blades, all of the plugins on top
of SIM will work as it is without any changes.

nPars and Blade Link Domain

Unlike other partitionable systems, the nPars are associated to the Blade Link Domain to which
they belong and there is no notion of a Complex node.

nPars and VC profiles

Each of the Monarchs in a Blade Link Domain can be assigned a VC profile. Once a VC profile
is assigned, the details of the same can be seen even in SIM.

Differences between Superdome 2 nPars and BL8x0c i4 nPars

The following table shows differences between nPars on Superdome 2 and nPars on BL8x0c i4
servers:

Table 11

Superdome 2 nPars

BL8x0c i4 nPars

Management Processors are never associated to nPars

Management Processors are associated to nPars

nPars are associated to the Complex to which they belong

nPars are associated to the Blade Link Domain to which
they belong

There is no notion of Auxiliary Blades

Auxiliary blades are present, but never represented in SIM.

Changes in partition configurations are notified by
WSMAN events from parcon

Changes in partition configurations are notified by SNMP
traps from OA

Debugging BL8x0c i4 nPars problems

Always ensure the output of SYSSET command shows correct Model information reflecting the
present partition configuration.

For more details, refer to the HP Integrity BL860c i4, BL870c i4 & BL890c i4 Server Blade HP
User Service Guide
at

http://www.hp.com/go/Blades-docs.

http://www.hp.com/go/Blades-docs

for BL8x0c i4 nPars support in HP SIM.

Configuring Onboard Administrator to send traps to CMS

The Central Management Server IP address needs to be added in the SNMP settings of Onboard
Administrator to allow Onboard Administrator send traps to the CMS. The steps are :

1.

Login to Onboard Administrator:

https:///

https:///

2.

Navigate to Enclosure Information -> Enclosure Settings -> SNMP Settings.

3.

Enter the IP Address or Fully Qualified Domain Name of the CMS in the Host section and
Community String of the CMS in Community String section.

4.

Click on Add button to add the CMS to the trap listeners list.

5.

A test alert can be sent to ensure CMS receives the trap by clicking on Send Test Alert button.

nPars and Blade Link Domain

43