System battery replacement – HP ProLiant DL320e Gen8 v2-Server User Manual

Page 76

background image

System battery replacement 76

System battery replacement

If the server no longer automatically displays the correct date and time, then replace the battery that provides

power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING:

The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page

14

).

2.

Remove the power from the server:

a.

Disconnect the power cord from the power source.

b.

Disconnect the power cord from the server.

3.

Do one of the following:

o

Extend the server from the rack (on page

14

).

o

Remove the server from the rack (on page

16

).

4.

Remove the access panel (on page

17

).

5.

Remove the air baffle (on page

18

).

6.

Locate the battery on the system board ("

System board components

" on page

9

).

7.

Remove the battery.