beautypg.com

Installing a storage controller – HP ProLiant DL320e Gen8 v2-Server User Manual

Page 38

background image

Hardware options installation 38

Upgrade options exist for an integrated array controller. For a list of supported options, see the product

QuickSpecs on the HP Product Bulletin website (

http://www.hp.com/go/productbulletin

).

To configure arrays, see the HP Smart Storage Administrator User Guide on the HP website

(

http://www.hp.com/go/smartstorage/docs

).

The server supports FBWC. FBWC consists of a cache module and a capacitor pack. The DDR cache module

buffers and stores data being written by the controller. When the system is powered on, the capacitor pack
fully charges in approximately 5 minutes. If a system power failure occurs, a fully charged capacitor pack

provides power for up to 80 seconds. During that interval, the controller transfers the cached data from DDR

memory to flash memory, where the data remains indefinitely or until a controller retrieves the data.
The data protection and the time limit also apply if a power outage occurs. When power is restored to the
system, an initialization process writes the preserved data to the storage drives.

CAUTION:

The cache module connector does not use the industry-standard DDR3 mini-DIMMs.

Do not use the controller with cache modules designed for other controller models, because the

controller can malfunction and you can lose data. Also, do not transfer this cache module to an

unsupported controller model, because you can lose data.

CAUTION:

To prevent a server malfunction or damage to the equipment, do not add or remove

the capacitor pack while an array capacity expansion, RAID level migration, or stripe size

migration is in progress.

CAUTION:

After the server is powered down, wait for 30 seconds, and then check the amber LED

before unplugging the cable from the cache module. If the amber LED flashes after 30 seconds,
do not remove the cable from the cache module. The cache module is backing up data. Data will

be lost if the cable is detached when the amber LED is still flashing.

IMPORTANT:

The capacitor pack might have a low charge when installed. If the pack does have

low charge a POST error message appears when the server is powered up, indicating that the

capacitor pack is temporarily disabled. No action is necessary. The internal circuitry

automatically recharges the capacitors and enables the capacitor pack. This process might take
up to 4 hours. During this time, the cache module functions properly but without the performance

advantage of the capacitor pack.

Installing a storage controller

IMPORTANT:

For additional installation and configuration information, see the documentation

that ships with the option.

To install the component:

1.

Power down the server (on page

14

).

2.

Remove the power from the server:

a.

Disconnect the power cord from the power source.

b.

Disconnect the power cord from the server.

3.

Do one of the following:

o

Extend the server from the rack (on page

14

).

o

Remove the server from the rack (on page

16

).

4.

Remove the access panel (on page

17

).