beautypg.com

Fbwc module led definitions – HP ProLiant DL320e Gen8 v2-Server User Manual

Page 12

background image

Component identification 12

Item LED

Status

Definition

Off

Removing the drive does not cause a logical drive to fail.

4

Drive status

Solid green

The drive is a member of one or more logical drives.

Flashing green

The drive is rebuilding or performing a RAID migration, strip size

migration, capacity expansion, or logical drive extension, or is
erasing.

Flashing

amber/green

The drive is a member of one or more logical drives and predicts

the drive will fail.

Flashing amber The drive is not configured and predicts the drive will fail.

Solid amber

The drive has failed.

Off

The drive is not configured by a RAID controller.

FBWC module LED definitions

The FBWC module has three single-color LEDs (one amber and two green). The LEDs are duplicated on the
reverse side of the cache module to facilitate status viewing.

1 - Amber

2 - Green

3 - Green

Interpretation

Off

Off

Off

The cache module is not powered.

Off

Flashing 0.5 Hz Flashing 0.5 Hz The cache microcontroller is executing from within its

boot loader and receiving new flash code from the host

controller.

Off

Flashing 1 Hz

Flashing 1 Hz

The cache module is powering up, and the capacitor

pack is charging.

Off

Off

Flashing 1 Hz

The cache module is idle, and the capacitor pack is

charging.

Off

Off

On

The cache module is idle, and the capacitor pack is

charged.

Off

On

On

The cache module is idle, the capacitor pack is charged,

and the cache contains data that has not yet been

written to the drives.

Off

Flashing 1 Hz

Off

A backup is in progress.

Off

On

Off

The current backup is complete with no errors.

Flashing 1 Hz

Flashing 1 Hz

Off

The current backup failed, and data has been lost.