beautypg.com

HP Storage Mirroring Software User Manual

Page 103

background image

15 - 17

5108

Failover

Error

The source machine %1 is

not responding to a ping.

This occurs when all

monitored IP addresses on

the source machine stop

responding to pings.

Countdown to failover will

begin at the first occurrence

and will continue until the

source machine responds or

until failover occurs.

5109

Failover

Error

The public NIC on source

machine %1 is not

responding to a ping.

The failover target did not

receive an answer to its ping

of the source machine.

Eventually, a failover will

result. Investigate possible

errors (down server, network

error, etc.).

5200

Failback

Info..

Failback completed for %1.

No action required.

5201

Failback

Info..

IP address %1 was removed

from target machine's %2

adapter.

No action required.

5202

Failback

Error

Unable to Failback properly

because IP address %1 was

missing a corresponding

SubNet Mask.

Contact technical support.

5300

Monitoring

Info.

The following IP address was

added to target's monitoring

list: %1

No action required.

5301

Monitoring

Info.

The following IP address was

removed from target's

monitoring list: %1

No action required.

5302

Monitoring

Info.

Drive share information for

%1 has been updated on the

target machine.

No action required.

5500

Service

Warning

Could not connect to e-mail

server. Check to make sure

the SMTP server %1 is

available (error code: %2).

Storage Mirroring could not

connect to your SMTP server

or the username and/or

password supplied is

incorrect. Verify that SMTP

server is available and that

you have identified it

correctly in your e-mail

notification configuration.

Also verify that your

username and password

have been entered correctly.

5501

Service

Warning

E-mail notification could not

be enabled (error code: %1).

This alert occurs if there is an

unexpected error enabling

e-mail notification during

daemon startup. Check to

see if any other errors

related to e-mail notification

have been logged. Also,

check to make sure the

Windows Management

Instrumentation (WMI)

daemon is enabled. If neither

of these apply, contact

technical support.

ID

Category

Severity

Event Message

Required Response

This manual is related to the following products: