beautypg.com

Power led, Cartridge a, 3 power led – HP RDX Removable Disk Backup System User Manual

Page 29

background image

Power LED

Table 3 Power LED

LED Status

Meaning

Action required

OFF

No power

Check the power cable connection and replace the cable

if necessary. You can use the power cable from your

monitor or another device to check that the connection is

working.
If the power supply is present and the LED remains off,

power cycle or reset the drive. If it still fails, call for

service.

Steady GREEN

The drive is ready

for operation

None. This is normal.

Blinking GREEN

Ejecting

None. The unit is ejecting the cartridge.

Steady AMBER

Fault

The unit has detected a fault condition. This may be

because:

the unit cannot eject the cartridge due to an

obstruction

the internal electronics are damaged or

malfunctioning

Use a straightened paper clip in the Emergency Eject

Hole to remove a stuck cartridge, as described in

Emergency eject

” on page 30. If this does not resolve

the problem, run the RDX diagnostic application.

Blinking AMBER

Prevent

None. The host server is accessing the media and the

user has pressed the eject button. The unit will blink

amber for a few seconds then return to steady green.

Wait for host access to complete, after which the unit

will eject the cartridge. If it does not, you may not be

running the correct RDX utility, see

RDX Removable Disk

utility

” on page 12. Install the RDX utility and try again.

If necessary, use Windows Explorer to eject the cartridge

(right-click on the drive letter for the RDX Removable Disk

Backup System and select Eject).

RDX Removable Disk Backup System

29