Creating a criticalvmhost collection, Vmware esx server guest system page – HP Insight Control Software for Linux User Manual
Page 17

1
Requires VMware vCenter Server.
NOTE:
VMM supports only the deployment of templates via SCVMM.
Configuring the polling frequency for virtual machine status checks
Insight Control virtual machine management provides a configurable parameter,
VMConfigRefreshRate
. This parameter controls the frequency with which VMM checks for
changes in virtual machine configuration, such as number of NICs on the virtual machine, size of
the hard disk, and so on. Configuration changes on the virtual machines are updated by VMM.
The default polling frequency is 5 seconds.
Add the following configurable parameter in the hpvmm.conf file found in the CMS location CMS>/bin: VMConfigRefreshRate=< For example, VMConfigRefreshRate = 5000 The value of the parameter can be between 5 seconds and 5 minutes. Any values entered outside Increasing the polling frequency reduces the ability of VMM to identify the changes in virtual Creating a CriticalVmHost collection To create a new collection: From the left pane of the HP SIM screen, click Customize, and then click New. The New 2. Click Choose members by attributes. 3. Select the collection criteria as shown in the screen, and then save the collection as . VMware ESX Server Guest System page When using a VMware ESX Server, from the Guest System page, click Launch vCenter. Configuring the polling frequency for virtual machine status checks 17
this range are automatically adjusted to the max/min value of the range.
machine status.
1.
Collection screen appears.
CriticalVmHost