Description
Script code
(15) Waits for command termin-
ation.
TIMEOUT=0 ...(15)
(16) User processing for pair
splitting.
[SPLIT_PROC] ...(16)
# Target pair volumes: SI11 dev group
[CMD]
(17) Batch splitting with a pair
group specified
CMDLINE=C:\HORCM\etc\pairsplit.exe -g TC01
-FBC 0 ...(17)
(18) Specifies a remote copy.
ENV=HORCC_MRCF= ...(18)
(19) Specifies an instance num-
ber.
ENV=HORCMINST=0 ...(19)
(20) If a non-zero return value
returns, the script will terminate
with an error.
END_CODE=TERMINATE_NZ ...(20)
(21) If the command does not
terminate within
10
seconds, the
script will terminate with an er-
ror.
TIMEOUT=10 ...(21)
[CMD]
(22) Checks the
sql01
pair
status.
Waits until the
sql01
status
becomes
PSUS
.
CMDLINE=C:\HORCM\etc\pairevtwait.exe -g TC01
-d sql01 -s psus -t 600 -FBC 0 ...(22)
(23) Specifies an instance num-
ber.
ENV=HORCMINST=0 ...(23)
(24) If a non-zero return value
returns, the script will terminate
with an error.
END_CODE=TERMINATE_NZ ...(24)
(25) Waits for command termin-
ation.
TIMEOUT=0 ...(25)
[CMD]
Operation for SQL Server databases
364
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- P2000 G3 MSA Array Systems (58 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)