HP StorageWorks XP Remote Web Console Software User Manual
Page 84
84
Configuring external LUs
For this example, LDEVs created from the first external LU are mapped to 00:00, 00:02, and 00:04,
respectively. The starting CU:LDEV number of LDEVs created from the second external LU is 00:06, and
subsequent LDEVS are mapped to 00:08 and 00:0A. The starting CU:LDEV number of LDEVs created
from the third external LU is 00:0C, and subsequent LDEVs are mapped to 00:0E and 00:10.
•
LDEV map
Each cell in the map represents an internal XP CU and LDEV number. Select a cell for the internal LDEV
on the map. The selected cell turns blue, and the LU of the selected cell becomes the first CU:LDEV
number of the mapped destination LUs. Defined (in use) internal LDEVs appear in gray, and internal
LDEVs to be mapped appear in white.
•
Clear button
Releases the cell selected on the LDEV map.
•
OK button
Closes the Select LDEV window, and returns to the Auto Map Setting window. On the Auto Map Setting
window, the CU:LDEV number you selected on the Select LDEV window as the head CU:LDEV number
of the mapped destination internal LDEVs appears in Start CU:LDEV.
•
Cancel button
Cancels all settings in the Select LDEV window, and returns to the Auto Map Setting window.
To map multiple external LUs as internal LDEVs at one time:
1.
Select the LU Operation tab. The LU Operation pane appears.
2.
In the Device tree, select Discovery. WWNs identifying the external array port that can be connected
appear in the tree.
3.
In the Device tree, select the port (WWN) you want to connect from the WWNs displayed. External LUs
that can be connected from the port (WWN) selected in the tree appear in the Device list.
4.
In the Device list, select the external LUs you want to map as internal LDEVs, right-click, and select Add
LU (Auto). The Auto Map Setting window (
) appears.
5.
Set the attributes for the external LUs you selected on the Device list.
NOTE:
Attributes for all LUs mapped at one time are identical.
• To select the first CU:LDEV number of the mapped destination internal LDEVs and the mapping
interval, go to
• To let External Storage XP select the first CU:LDEV number, go to
6.
Click Select LDEV. The Select LDEV window appears.
7.
Select the first CU:LDEV number of the mapped destination internal LDEVs and the mapping interval.
8.
Click OK. The Auto Map Setting window appears.
9.
If you do not want to automatically set the primary and alternate paths, but you want to specify the
paths to be set as candidates for the primary and alternate paths, click Select Paths. The Select Paths
window appears.
To automatically set alternate paths, go to
10.
Select the path and exclude it from the list of the candidates for the primary and alternate paths. For
instructions, see ”
Mapping external LUs individually (Add LU)
11.
Click OK. The Auto Map Setting window appears.
12.
Click OK. The Auto Map Setting window closes, and mapping the internal CU:LDEV numbers to the
external LUs starts.
NOTE:
If the CU:LDEV numbers cannot be mapped properly because too many external LUs are
selected on the Device list, all processing is canceled and the message pane appears.
• After the CU:LDEV number mapping is complete, if the SSID setting is required, the SSID window
) appears. Go to