beautypg.com

HP StorageWorks XP Remote Web Console Software User Manual

Page 84

background image

84

Configuring external LUs

For this example, LDEVs created from the first external LU are mapped to 00:00, 00:02, and 00:04,

respectively. The starting CU:LDEV number of LDEVs created from the second external LU is 00:06, and

subsequent LDEVS are mapped to 00:08 and 00:0A. The starting CU:LDEV number of LDEVs created

from the third external LU is 00:0C, and subsequent LDEVs are mapped to 00:0E and 00:10.

LDEV map
Each cell in the map represents an internal XP CU and LDEV number. Select a cell for the internal LDEV

on the map. The selected cell turns blue, and the LU of the selected cell becomes the first CU:LDEV

number of the mapped destination LUs. Defined (in use) internal LDEVs appear in gray, and internal

LDEVs to be mapped appear in white.

Clear button
Releases the cell selected on the LDEV map.

OK button
Closes the Select LDEV window, and returns to the Auto Map Setting window. On the Auto Map Setting

window, the CU:LDEV number you selected on the Select LDEV window as the head CU:LDEV number

of the mapped destination internal LDEVs appears in Start CU:LDEV.

Cancel button
Cancels all settings in the Select LDEV window, and returns to the Auto Map Setting window.

To map multiple external LUs as internal LDEVs at one time:

1.

Select the LU Operation tab. The LU Operation pane appears.

2.

In the Device tree, select Discovery. WWNs identifying the external array port that can be connected

appear in the tree.

3.

In the Device tree, select the port (WWN) you want to connect from the WWNs displayed. External LUs

that can be connected from the port (WWN) selected in the tree appear in the Device list.

4.

In the Device list, select the external LUs you want to map as internal LDEVs, right-click, and select Add

LU (Auto). The Auto Map Setting window (

Figure 48

) appears.

5.

Set the attributes for the external LUs you selected on the Device list.

NOTE:

Attributes for all LUs mapped at one time are identical.

• To select the first CU:LDEV number of the mapped destination internal LDEVs and the mapping

interval, go to

step 6

.

• To let External Storage XP select the first CU:LDEV number, go to

step 9

.

6.

Click Select LDEV. The Select LDEV window appears.

7.

Select the first CU:LDEV number of the mapped destination internal LDEVs and the mapping interval.

8.

Click OK. The Auto Map Setting window appears.

9.

If you do not want to automatically set the primary and alternate paths, but you want to specify the

paths to be set as candidates for the primary and alternate paths, click Select Paths. The Select Paths

window appears.
To automatically set alternate paths, go to

step 12

.

10.

Select the path and exclude it from the list of the candidates for the primary and alternate paths. For

instructions, see

Mapping external LUs individually (Add LU)

” on page 73.

11.

Click OK. The Auto Map Setting window appears.

12.

Click OK. The Auto Map Setting window closes, and mapping the internal CU:LDEV numbers to the

external LUs starts.

NOTE:

If the CU:LDEV numbers cannot be mapped properly because too many external LUs are

selected on the Device list, all processing is canceled and the message pane appears.

• After the CU:LDEV number mapping is complete, if the SSID setting is required, the SSID window

(

Figure 46

) appears. Go to

step 13

.

This manual is related to the following products: