128 Notes on connecting external arrays

NOTE:

When using the Thunder 9500V subsystem as an external array, the following versions are

recommended. If you use a 9500V subsystem whose version is earlier than the following versions, the

SATA drive’s information might not be displayed correctly.

For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later

For Thunder 9580V, Thunder 9585V: version 1658 or later

Common 1

Delay Planned Shutdown

You can either specify this parameter or

omit specifying this parameter.

OPTION 1

SCSI Fibre Channel Common Options

You can either specify this parameter or

omit specifying this parameter.

OPTION 2

SCSI Fibre Channel Common Options

You can either specify this parameter or

omit specifying this parameter.

Data Striping

Operation if the processor failure occurs

Set this parameter to Reset of occurred.

Inquiry Setting

Command Queuing Mode

Set this parameter to ON.

Vendor ID

Keep this parameter as HITACHI (default),

and do not change.

Product ID

Keep this parameter as DF600F (default),

and do not change.

ROM Microprogram Version

You can either specify this parameter or

omit specifying this parameter.

RAM Microprogram Version

You can either specify this parameter or

omit specifying this parameter.

WEB Title

You can either specify this parameter or

omit specifying this parameter.

Port Type

Reset/LIP Mode

Reset/LIP Mode (Signal)

You can either specify this parameter or

omit specifying this parameter.

Reset/LIP Mode (Process)

You can either specify this parameter or

omit specifying this parameter.

LIP Reset Mode

You can either specify this parameter or

omit specifying this parameter.

Controller Option

RS232C Error Information Outflow Mode

You can either specify this parameter or

omit specifying this parameter.

Write and verify mode

Set this parameter to ON.

Host Connection Mode

Host Connection Mode 1

Set this parameter to Standard Mode.

Host Connection Mode 2

Specify HISUP Mode.

NOTE:

Do not specify any other

parameters.

Table 13

System parameter settings (Thunder 9500V subsystems) (continued)

Pane name

Parameter

Parameter setting

This manual is related to the following products: