beautypg.com

Table 9 mapped external lu status values, 9 mapped external lu status values – HP StorageWorks XP Remote Web Console Software User Manual

Page 59

background image

External Storage XP user guide

59

• LDEV Status: Mapped external LU’s status. Possible values: Normal, Unknown, Blockade, Warning,

and Format.

Product name of the connected external array
• ExG: External LU group number. This appears when you group the LUs from one or more external

arrays under a common number.

• Serial: Product serial number.
• Product: Product name.
• Vendor: Vendor name.
• Ex-Dev. Status: Status of the operation executed on the external array, or status of the path

connection. Possible values: Normal, Unknown, Blockade, Warning, Checking, Cache Destage,

and Disconnect. For a description of these values, see

Table 8

.

• LDEV Status: Mapped external LU’s status. Possible values: Normal, Unknown, Blockade, Warning,

and Format. For a description of these values, see

Table 9

.

External LU group number
• Characteristic: External LU’s identification number.
• Device: External LU’s device name.
• Capacity: External LU’s capacity in 512-byte blocks.
• Ex-Dev. info.: External array information. When the external array is an XP1024/XP128 or

TagmaStore Workgroup Modular Storage (WMS) array, an asterisk (*) appears.

• VMA: Information about the VMA setting by LUN Security XP Extension. When VMA is set for the

volume, an asterisk (*) appears.

• Alter. Path: Number of configured paths in the format The number of valid paths (the number of

primary alternate paths).

• IO Suppression: I/O Suppression mode: Enable or Disable. For more information, see ”

External LU

attributes set by mapping

” on page 20.

• Cache Mode: Cache mode: Enable or Disable. For more information, see

External LU attributes set

by mapping

” on page 20.

• Path: When paths are set, an asterisk (*) appears.
• Group: External LU group number and reference number assigned to each LU in the external LU

group. External Storage XP automatically assigns reference numbers to LUs in the group when

external LUs are mapped. This appears in the format “external LU group number - reference

number of the LU in the group”.

Warning

FC path or paths have an abnormal status. Check the status of the paths.

Checking

External Storage XP is verifying configuration information defined for FC paths.

Cache Destage

External Storage XP is writing all data in the local array cache memory to the LU.

Disconnect

Connection to external array or external LU was intentionally stopped using the

Disconnect Subsystem or Disconnect Volume command.

Table 9

Mapped external LU status values

LDEV status

Description

Normal

LDEV status is normal.

Unknown

LDEV status has yet to be ascertained.

Blockade

I/O traffic to the LDEV is not permitted.

Warning

External LUs have abnormal status.

Format

Volume is in the process of being formatted.

Table 8

External array status values (continued)

LU status

Description

This manual is related to the following products: