Error code
Error message
Comment or clarification
2825
Invalid array.
The array ID is invalid.
2826
Array not specified.
The script file has commands that require an array, but no
array is specified.
2827
New array ID does not
match the next available
array ID.
The scripted array ID is not the next ID in sequence, based on
the IDs of the existing arrays. For example, only array A
exists and the script file specifies creation of array C (omitting
array B).
2828
New array ID already
exists.
This error occurs in Configure mode when the array ID
specified in the script file already exists in the configuration.
In Configure mode, you can create only new arrays.
2829
Cannot create array.
The controller has no unassigned physical drives, or it
already has the maximum number of arrays or logical drives.
2830
Cannot expand array.
The controller does not support expansion, or the current
controller configuration is not expandable.
2831
Cannot change array
spare.
This error message appears if you try to change the number
of spares in an array when the configuration does not
support the addition or subtraction of spares.
2832
Invalid physical drive.
A specified physical drive is not a valid physical drive, or it
cannot be placed in the array.
2833
Invalid spare.
A specified spare is not a valid spare drive, or it cannot be
placed in the array as a spare.
2834
Invalid logical drive.
—
2835
Logical drive not specified.
The script file has commands that require a logical drive, but
no logical drive is specified.
2836
New logical drive ID does
not match the next available
logical drive ID.
The script file specifies a logical drive ID that is not the first
unused ID in the sequence. For example, this message
appears if the controller has only logical drive 1 and the
script file specifies creation of logical drive 3 (omitting logical
drive 2). A common cause of this error is that the input file
specifies nonsequential logical drive numbers. In this case,
change the logical drive numbers in the input file so that they
are sequential.
2837
New logical drive ID
already exists.
This error occurs in Configure mode when the logical drive ID
specified in the script file already exists in the configuration.
In Configure mode, you can create only new logical drives.
2838
Cannot create logical drive. The array has no free space, or the maximum number of
logical drives has already been reached.
2839
Cannot migrate logical
drive RAID.
The controller does not support RAID migration, or migration
is not possible with the current controller configuration.
2840
Cannot migrate logical
drive stripe size.
The controller does not support stripe size migration, or
migration is not possible with the current controller
configuration.
2841
Cannot extend logical
drive.
The controller does not support extension, or the current
controller configuration cannot be extended. For example,
extension is not possible if the array has no free space.
2842
Invalid RAID.
The specified RAID level is invalid or is not possible with the
current configuration.