Toolkit utilities 50

Error code

Error message

Comment or clarification

2825

Invalid array.

The array ID is invalid.

2826

Array not specified.

The script file has commands that require an array, but no

array is specified.

2827

New array ID does not

match the next available
array ID.

The scripted array ID is not the next ID in sequence, based on

the IDs of the existing arrays. For example, only array A
exists and the script file specifies creation of array C (omitting

array B).

2828

New array ID already

exists.

This error occurs in Configure mode when the array ID

specified in the script file already exists in the configuration.
In Configure mode, you can create only new arrays.

2829

Cannot create array.

The controller has no unassigned physical drives, or it
already has the maximum number of arrays or logical drives.

2830

Cannot expand array.

The controller does not support expansion, or the current
controller configuration is not expandable.

2831

Cannot change array
spare.

This error message appears if you try to change the number
of spares in an array when the configuration does not

support the addition or subtraction of spares.

2832

Invalid physical drive.

A specified physical drive is not a valid physical drive, or it

cannot be placed in the array.

2833

Invalid spare.

A specified spare is not a valid spare drive, or it cannot be

placed in the array as a spare.

2834

Invalid logical drive.

2835

Logical drive not specified.

The script file has commands that require a logical drive, but

no logical drive is specified.

2836

New logical drive ID does

not match the next available
logical drive ID.

The script file specifies a logical drive ID that is not the first

unused ID in the sequence. For example, this message
appears if the controller has only logical drive 1 and the

script file specifies creation of logical drive 3 (omitting logical
drive 2). A common cause of this error is that the input file
specifies nonsequential logical drive numbers. In this case,

change the logical drive numbers in the input file so that they
are sequential.

2837

New logical drive ID

already exists.

This error occurs in Configure mode when the logical drive ID

specified in the script file already exists in the configuration.
In Configure mode, you can create only new logical drives.

2838

Cannot create logical drive. The array has no free space, or the maximum number of

logical drives has already been reached.

2839

Cannot migrate logical

drive RAID.

The controller does not support RAID migration, or migration

is not possible with the current controller configuration.

2840

Cannot migrate logical

drive stripe size.

The controller does not support stripe size migration, or

migration is not possible with the current controller
configuration.

2841

Cannot extend logical
drive.

The controller does not support extension, or the current
controller configuration cannot be extended. For example,

extension is not possible if the array has no free space.

2842

Invalid RAID.

The specified RAID level is invalid or is not possible with the

current configuration.