beautypg.com

Sspadapterswithaccess, Stripesize, Hba category – HP SmartStart-Software User Manual

Page 47

background image

Toolkit utilities 47

In Reconfigure mode, the default setting is the existing size of the logical drive. If you enter a larger value,
ACU extends the logical drive to the new size if there is unused drive capacity on the same array, as long

as the operating system supports logical drive extension. You cannot reduce the size of the logical drive.

CAUTION:

Back up all data before extending a logical drive.

SSPAdaptersWithAccess

Enter values here to identify the SSP adapters that you want to have access to a logical drive. The values
are processed only if either SSPState or LogicalDriveSSPState is set to Enable. Otherwise, the values are

ignored.

NOTE:

Be sure that every HBA in the system has access to the logical drives for which multi-

path will be used.

StripeSize

You can enter a numerical value for this option to specify the size of the data stripes (in kilobytes), or you
can leave this option blank and allow ACU to use a default value.
The valid stripe size values depend on the RAID level.

For RAID 0, RAID 1, or RAID 1+0 arrays, you can enter any of the stripe size values listed in the

sample script.

For RAID 5 arrays, the maximum stripe size in most cases is 256 KB, but old controller models are

often limited to 64 KB.

For RAID 6 arrays, the maximum stripe size is either 64 KB or 256 KB, depending on the controller.

The default stripe size value depends on the action mode.

In Configure action mode, the default value is determined by the RAID level that you specified earlier

in the script. (In some cases, it also depends on the ACU version, the controller model, and the
controller firmware version).

o

For RAID 0, RAID 1, or RAID 1+0, the default value is 128 KB.

o

For RAID 5, the default value is usually 64 KB, but on some controller models it is 16 KB or 128
KB.

o

For RAID 6, the default value is usually 16 KB, but on some controller models it is 64 KB or 128
KB.

In Reconfigure action mode, the default value for this option is the stripe size that is already

configured for the logical drive. If you enter a value that is different from the existing stripe size,
ACU attempts to migrate the logical drive to the stripe size that you specify. (If you intend to migrate

the logical drive, back up all data before starting the migration procedure.)

HBA category

The HBA category has the following options:

ConnectionName (on page

48

)

HBA_WW_ID (on page

48

)

HostMode (on page

48

)

This manual is related to the following products: