Error code
Error message
Comment or clarification
1053
Cannot remove physical
drives from existing array.
This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than
already exist in the array. ACU interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so ACU prevents the
script from running.
1065-1066
Too many coinciding
expansion, migration, or
extension operations.
ACU does not support multiple simultaneous expansions,
migrations, or extensions without saving the configuration
between operations. Limit the number of such configuration
changes in the script.
1091
Controller does not support
SSP.
—
1093
Controller requires physical
drives to set license keys.
—
1102
Slot information is not
available.
You cannot run a script in Input mode on internal controllers
that do not have slot information online. Systems running
Microsoft®
Windows® must have the System Management
Driver loaded.
1110
Controller does not support
license keys.
—
1111
Invalid license key.
—
1112
Controller has maximum
number of license keys.
—
1114
Controller requires non-
failed physical drives to set
license keys.
—
2564
Controller is locked by
another machine or user.
—
2818
Invalid Method.
The scripted Method value is not valid.
2819
Invalid Controller.
The scripted controller does not match any existing
controllers.
2820
Could not detect controller
—
2821
No controllers detected.
This error applies to Input mode only. If no controllers are
detected in Capture mode, the capture file is empty.
2822
Invalid read cache/write
cache ratio.
The specified cache ratio is not supported by either the
controller or the current controller configuration.
2823
Invalid rebuild priority.
—
2824
Invalid expand priority.
This error message appears if the expand priority value
specified in the script is not supported. This message also
appears if expansion is not possible because the Expand
Priority feature is then not supported. (Expansion might be
temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,
another expansion or migration is already in progress, or the
array has the maximum supported number of physical
drives.)