Toolkit utilities 49

Error code

Error message

Comment or clarification

1053

Cannot remove physical
drives from existing array.

This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than

already exist in the array. ACU interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so ACU prevents the

script from running.

1065-1066

Too many coinciding

expansion, migration, or
extension operations.

ACU does not support multiple simultaneous expansions,

migrations, or extensions without saving the configuration
between operations. Limit the number of such configuration
changes in the script.

1091

Controller does not support
SSP.

1093

Controller requires physical

drives to set license keys.

1102

Slot information is not

available.

You cannot run a script in Input mode on internal controllers

that do not have slot information online. Systems running
Microsoft®

Windows® must have the System Management

Driver loaded.

1110

Controller does not support
license keys.

1111

Invalid license key.

1112

Controller has maximum
number of license keys.

1114

Controller requires non-
failed physical drives to set

license keys.

2564

Controller is locked by

another machine or user.

2818

Invalid Method.

The scripted Method value is not valid.

2819

Invalid Controller.

The scripted controller does not match any existing

controllers.

2820

Could not detect controller

.

2821

No controllers detected.

This error applies to Input mode only. If no controllers are

detected in Capture mode, the capture file is empty.

2822

Invalid read cache/write

cache ratio.

The specified cache ratio is not supported by either the

controller or the current controller configuration.

2823

Invalid rebuild priority.

2824

Invalid expand priority.

This error message appears if the expand priority value

specified in the script is not supported. This message also
appears if expansion is not possible because the Expand

Priority feature is then not supported. (Expansion might be
temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,

another expansion or migration is already in progress, or the
array has the maximum supported number of physical
drives.)