beautypg.com

Server specific troubleshooting, Minimum hardware configuration – HP ProLiant DL560 Server User Manual

Page 99

background image

99


Server Specific Troubleshooting

In This Section

Minimum Hardware Configuration ........................................................................................ 99
Server Error Messages.......................................................................................................... 100
When the Server Does Not Boot .......................................................................................... 100
Diagnostic Steps ................................................................................................................... 102
Problems After Initial Boot .................................................................................................. 106
ROMPaq Disaster Recovery................................................................................................. 108
Other Information Resources................................................................................................ 109

Minimum Hardware Configuration

Be sure that the server meets the requirements for a minimum hardware
configuration. During the troubleshooting process, it may be necessary to reduce
the system to its minimum configuration, reinstalling options one at a time to
determine the cause of failure.

Component Minimum

Requirements

Processor

A processor must be installed in processor 1 socket with a
PPM installed in PPM 1 slot.

Fans

The following fans must be installed:

Fan 1 (processor zone)

Fan 3 (processor zone)

Fan 5 (processor zone)

Fan 7 (processor zone)

Fan 9 (power supply zone)

Memory

Slots 1A and 2A must be populated with ECC Registered
DDR SDRAM DIMMs.

Hard Drives

One hard drive must be installed.

HP CONFIDENTIAL