beautypg.com

HP ProLiant DL560 Server User Manual

Page 21

background image

Server

Component

Identification

21

System LED and
Color

Internal Health
LED Color

Status

Processor failure,
socket X (Amber)

Red

Processor in socket X has failed.

Processor in socket X failed over to the offline spare.

Processor

X is not installed in the socket.

Processor

X is unsupported.

ROM detects a failed processor during POST.

Amber

Processor in socket X is in a pre-failure condition.

Processor failure, two
or more sockets
(Amber)

Red

Processor types are mismatched.

PPM failure, slot X
(Amber)

Red

PPM in slot X has failed.

PPM is not installed in slot X, but the corresponding
processor is installed.

DIMM failure, slot X
(Amber)

Red

DIMM in slot X has failed.

DIMM in slot X is an unsupported type, and no valid
memory exists in another bank.

Amber

DIMM in slot X has reached single-bit correctable
error threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid
memory exists in another bank.

Overtemperature
(Amber)

Red

Health Driver has detected a cautionary temperature
level.

Server has detected a hardware critical temperature
level.

Riser interlock
(Amber)

Red

PCI riser cage is not seated.

Peripheral board
interlock (Amber)

Red

Peripheral board is not seated.

Fan (Amber)

Amber

Redundant fan has failed.

Red

The minimum fan requirements are not being met. One
or more fans have failed or are missing.

HP CONFIDENTIAL

File Name: 303212-1new.doc Last Saved On: 11/4/02 10:51 AM