Installation Requirements

WARNING: To reduce the risk of electric shock, personal

injury, and damage to the equipment:

Do not attempt to service any parts of the equipment other than
those specified in the following procedure. Any other activities
may require that you shut down the server and remove the
power cord.

Installation and maintenance of this product must be performed
by individuals who are knowledgeable about the procedures,
precautions and hazards associated with the product.

You must observe the following requirements when installing redundant hot-plug
fans:

To ensure optimum cooling, populate the primary fan locations, 1, 3, 5, 7,
and 9, before populating the redundant locations.

If a primary fan fails, replace the nonfunctioning fan before installing fans in
redundant locations.

Installing Redundant Hot Plug Fans

1. Extend the server from the rack, if applicable ("Extending the Server from

the Rack" on page 30).

2. Remove the access panel ("Removing the Access Panel" on page 32).