beautypg.com

Is a connected port’s ethernet link status led off, Is the power supply’s ac power good led off – HP StorageWorks 2000fc G2 Modular Smart Array User Manual

Page 46

background image

46

Troubleshooting

Is a connected port’s Expansion Port Status LED off?

Is a connected port’s Ethernet link status LED off?

Is the power supply’s AC Power Good LED off?

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The link is down.

Check cable connections.

Reseat cables.

Replace cables.

In SMU, review the event logs for

indicators of a specific fault in a

host data path component.

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The link is down.

Use standard networking

troubleshooting procedures to isolate

faults on the network.

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply is not receiving

adequate power.

Verify that the power cord is

properly connected and check the

power source it is connected to.

Check that the power supply FRU is

firmly locked into position.

Check the event log for specific

information regarding the fault.

Isolate the fault.

Contact an authorized service

provider for assistance.