beautypg.com

Hard drive leds, 5 hard drive led combinations, Table 5 – HP StorageWorks 2000fc G2 Modular Smart Array User Manual

Page 32

background image

32

LED descriptions

Hard drive LEDs

LED

Description

1

Fault/UID (amber/blue)

2

Online/Activity (green)

Table 5

Hard drive LED combinations

Online/Activity (green)

Fault/UID (amber/blue)

Description

On

Off

Normal operation. The drive is online, but it

is not currently active.

Blinking irregularly

Off

The drive is active and operating normally.

Off

Amber; blinking regularly (1 Hz)

Offline; the drive is not being accessed. A

predictive failure alert may have been

received for this device. Further

investigation is required.

On

Amber; blinking regularly (1 Hz)

Online; no activity. A predictive failure alert

may have been received for this device.

Further investigation is required.

Blinking irregularly

Amber; blinking regularly (1 Hz)

The drive is active, but a predictive failure

alert may have been received for this drive.

Further investigation is required.

Off

Amber; solid

Offline; no activity. A critical fault condition

has been identified for this drive.

Off

Blue; solid

Offline. The drive has been selected by a

management application (SMU).

On or blinking

Blue; solid

The controller is driving I/O to the drive,

and it has been selected by a management

application (SMU).

1

2

1

2