Hot-plug fans – HP ProLiant DL585 G2 Server User Manual
Page 30
Operations 30
Hot-plug fans
The server supports redundant hot-plug fans ("
) in a 5+1 configuration to
provide proper airflow to the server.
WARNING:
To prevent personal injury from hazardous energy:
•
Remove watches, rings, or other metal objects.
•
Use tools with insulated handles.
•
Do not place tools or metal parts on top of batteries.
To replace a hot-plug fan:
1.
Extend the server from the rack ("
Extending the server from the rack
2.
Remove the access panel ("
3.
Identify the failed fan by locating an amber LED on top of the failed fan ("
page
) or on the Systems Insight Display ("
4.
Remove the malfunctioning hot-plug fan from the server.
IMPORTANT:
Remove and replace one fan at a time. If the system detects two fan failures, the
server shuts down to avoid thermal damage.
5.
Install a new hot-plug fan.
6.
Observe the LED on each installed fan to be sure it is illuminated green ("
page
NOTE:
If the front panel internal system health LED is not green after you install hot-plug fans,
reseat the hot-plug fan or refer to the troubleshooting section.
7.
Replace the access panel ("
8.
Slide the server into the rack.