Operations 30

Hot-plug fans

The server supports redundant hot-plug fans ("

Fan locations

" on page

18

) in a 5+1 configuration to

provide proper airflow to the server.

WARNING:

To prevent personal injury from hazardous energy:

Remove watches, rings, or other metal objects.

Use tools with insulated handles.

Do not place tools or metal parts on top of batteries.

To replace a hot-plug fan:

1.

Extend the server from the rack ("

Extending the server from the rack

" on page

27

).

2.

Remove the access panel ("

Removing the access panel

" on page

28

).

3.

Identify the failed fan by locating an amber LED on top of the failed fan ("

Hot-plug fan LEDs

" on

page

19

) or on the Systems Insight Display ("

Systems Insight Display LEDs

" on page

16

).

4.

Remove the malfunctioning hot-plug fan from the server.

IMPORTANT:

Remove and replace one fan at a time. If the system detects two fan failures, the

server shuts down to avoid thermal damage.

5.

Install a new hot-plug fan.

6.

Observe the LED on each installed fan to be sure it is illuminated green ("

Hot-plug fan LEDs

" on

page

19

).

NOTE:

If the front panel internal system health LED is not green after you install hot-plug fans,

reseat the hot-plug fan or refer to the troubleshooting section.

7.

Replace the access panel ("

Removing the access panel

" on page

28

).

8.

Slide the server into the rack.