Action event messages – HP Integrity NonStop H-Series User Manual
Page 220
![background image](/manuals/397556/220/background.png)
Error Messages
HP NonStop AutoTMF Software User’s Guide—429952-013
D-8
Action Event Messages
430
Cause. An authorized user requested a NonStop AutoTMF software process stop.
Effect. All automatic transactions were committed and the process has been
abended.
Recovery. Informational message only; no corrective action is needed.
433
Cause. The referenced product is licensed for a maximum number of logical NSK
processors (MAXCPUS). The number of active processors exceeds the license
maximum.
Effect. Your license is not valid.
Recovery. Contact the license manager requesting a valid license with sufficient
number of logical processors. Please provide your system serial number and order
number.
600
Cause. An unauthorized user attempted to start the monitor process.
Effect. The monitor process is not started.
Recovery. Start the monitor process with an authorized user ID.
Action Event Messages
701
Cause. A required program object file is missing from the product subvolume.
Effect. The process abends.
Recovery. Install the missing object file and re-run the program.
Process was stopped by user request
System contains more logical processors than permitted by
AutoTMF license.
Monitor start unauthorized
Product object missing