beautypg.com

Appb, Appendix b, Silo 9710 media manager troubleshooting – HP NonStop G-Series User Manual

Page 127

background image

Appendix B-1

APPENDIX B

SILO 9710 MEDIA MANAGER Troubleshooting

In this Appendix

This appendix includes the following main topics and sections:

Topic Section
Overview B.1
Troubleshooting B.2
Possible Problem Areas with TCP/IP B.3

B.1 Overview

This chapter will deal with most of the problems that may be encountered while
installing/configuring and using SILO 9710 MEDIA MANAGER. Most of the
problems will be TCP/IP, Tandem security or Tandem device setup related. By
far, the most prevalent problems are TCP/IP related and Hardware (i.e. TPTSTR).

B.2 Troubleshooting

Troubleshooting Chart Table 1

If…

Then…

The following action should be
taken.

When the connect button is
chosen in SMM, the Device
name field does not highlight
and an error about TCPIP
address or port # is received
being unable to connect

There is a problem
communicating with the
Tandem host

Verify the Tandem host IP# in the
Address field

Make sure the TCP/IP subsystem is
running on the Tandem host

Run Config program on the Tandem
and check to see if the port # that
was entered for the Tandem port #
field is the same as entered in the
GUI

Cannot Connect

There is a problem
communicating with the server
program

Shut down the GUI. Then type
OBEY STOPALL at the TACL
prompt. Wait 15-20 seconds.
Restart the server program first and
then the GUI. Reconnect