HP Linux Server Management Software User Manual
Page 54
Toolkit utilities 54
Error code
Error message
Comment or clarification
1112
Controller has maximum
number of license keys.
—
1114
Controller requires non-
failed physical drives to set
license keys.
—
2564
Controller is locked by
another machine or user.
—
2818
Invalid Method.
The scripted Method value is not valid.
2819
Invalid Controller.
The scripted controller does not match any existing
controllers.
2820
Could not detect controller
—
2821
No controllers detected.
This error applies to Input mode only. If no controllers are
detected in Capture mode, the capture file is empty.
2822
Invalid read cache/write
cache ratio.
The specified cache ratio is not supported by either the
controller or the current controller configuration.
2823
Invalid rebuild priority.
—
2824
Invalid expand priority.
This error message appears if the expand priority value
specified in the script is not supported. This message also
appears if expansion is not possible because the Expand
Priority feature is then not supported. (Expansion might be
temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,
another expansion or migration is already in progress, or the
array has the maximum supported number of physical
drives.)
2825
Invalid array.
The array ID is invalid.
2826
Array not specified.
The script file has commands that require an array, but no
array is specified.
2827
New array ID does not
match the next available
array ID.
The scripted array ID is not the next ID in sequence, based on
the IDs of the existing arrays. For example, only array A
exists and the script file specifies creation of array C (omitting
array B).
2828
New array ID already
exists.
This error occurs in Configure mode when the array ID
specified in the script file already exists in the configuration.
In Configure mode, you can create only new arrays.
2829
Cannot create array.
The controller has no unassigned physical drives, or it
already has the maximum number of arrays or logical drives.
2830
Cannot expand array.
The controller does not support expansion, or the current
controller configuration is not expandable.
2831
Cannot change array
spare.
This error message appears if you try to change the number
of spares in an array when the configuration does not
support the addition or subtraction of spares.
2832
Invalid physical drive.
A specified physical drive is not a valid physical drive, or it
cannot be placed in the array.
2833
Invalid spare.
A specified spare is not a valid spare drive, or it cannot be
placed in the array as a spare.