beautypg.com

HP Linux Server Management Software User Manual

Page 54

background image

Toolkit utilities 54

Error code

Error message

Comment or clarification

1112

Controller has maximum
number of license keys.

1114

Controller requires non-
failed physical drives to set

license keys.

2564

Controller is locked by

another machine or user.

2818

Invalid Method.

The scripted Method value is not valid.

2819

Invalid Controller.

The scripted controller does not match any existing

controllers.

2820

Could not detect controller

.

2821

No controllers detected.

This error applies to Input mode only. If no controllers are

detected in Capture mode, the capture file is empty.

2822

Invalid read cache/write

cache ratio.

The specified cache ratio is not supported by either the

controller or the current controller configuration.

2823

Invalid rebuild priority.

2824

Invalid expand priority.

This error message appears if the expand priority value

specified in the script is not supported. This message also
appears if expansion is not possible because the Expand
Priority feature is then not supported. (Expansion might be

temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,
another expansion or migration is already in progress, or the

array has the maximum supported number of physical
drives.)

2825

Invalid array.

The array ID is invalid.

2826

Array not specified.

The script file has commands that require an array, but no

array is specified.

2827

New array ID does not

match the next available
array ID.

The scripted array ID is not the next ID in sequence, based on

the IDs of the existing arrays. For example, only array A
exists and the script file specifies creation of array C (omitting

array B).

2828

New array ID already

exists.

This error occurs in Configure mode when the array ID

specified in the script file already exists in the configuration.
In Configure mode, you can create only new arrays.

2829

Cannot create array.

The controller has no unassigned physical drives, or it
already has the maximum number of arrays or logical drives.

2830

Cannot expand array.

The controller does not support expansion, or the current
controller configuration is not expandable.

2831

Cannot change array

spare.

This error message appears if you try to change the number

of spares in an array when the configuration does not
support the addition or subtraction of spares.

2832

Invalid physical drive.

A specified physical drive is not a valid physical drive, or it

cannot be placed in the array.

2833

Invalid spare.

A specified spare is not a valid spare drive, or it cannot be

placed in the array as a spare.

This manual is related to the following products: