Unix ibm, Ibm aix 3.2.5, Ibm rs/6000 systems – HP StorageWorks DLT VS80 Tape Drive User Manual
Page 29: Ibm rs/6000, Ibm rs/6000 aix
UNIX ibm
hp learning products
may have a later version
UNIX configuration
IBM RS/6000 AIX
This topic is available in English only. Click in the top right-hand corner to
close the window and return to the tape drive user's guide..
contents of this section
related topics
determining the SCSI id
Before you configure your system to support your new HP Surestore drive, you
need to determine what SCSI ID to use. The SCSI ID must be unique for each
device attached to the SCSI bus. To list the existing devices, use the following
command:
% lsdev -C |grep SCSI
This will produce output that looks similar to:
scsi0 Available 00-00-0S Standard SCSI I/O Controller
hdisk0 Available 00-00-0S-0 1.0 GB SCSI Disk Drive
rmt1 Defined 00-00-0S-2,0 Other SCSI Tape Drive
The SCSI ID is in the series 00-00-0S-X,0 where X is the SCSI ID. Review the list
of existing SCSI IDs and choose an available ID to assign to your new tape drive.
configuring the device files
To install the HP Surestore Ultrium drive on an IBM workstation running AIX, you
will need to create the appropriate device files for the drive.
note:
Do not choose the
smit
option of "
4mm2gb
" as the Tape Device Type. This
is reserved for Connor drives. If you use it with HP drives, you will get the error
"
Device to be configured does not match the physical device
at the specified connection location
".
To change to variable block mode, use the following procedure:
1 If you are using a graphics terminal
running X-Windows, then at a Windows
terminal, type:
smit tape
If you are using a non-graphics termina
l, at the command line type:
% smit -C tape
2
If no device has been configured at this address before, select "
add a
tape drive
" to set up the address. From the pop-up window, select "
ost
"
or "
Other SCSI tape drive
" as the tape drive you wish to change and
choose connection addresses as appropriate.
3
Select from the window: "
change/show characteristics of a tape
drive
"
4
From the pop-up window, select "
ost
" or "
Other SCSI tape drive
" as
the tape drive you wish to change. Do not choose "
4mm2gb
".
5
Change the block size field to 0, and click on the "
DO
" button or press [Enter]
to apply the change.
HP drives will work with
tar
,
cpio
,
backup
,
restore
and
dd
. For systems other
than the 43P, the drive is also boot-capable, provided a boot tape is generated
using
mkszfile
and
mksysb
.
Once the device files have been created, you should confirm that your new tape
.
device file names under AIX
Use device filenames as listed below for the combination of Rewind on Close,
Retension on Open, and Compression that you want:
Filename Rewind on Close Retension on Open Compression
/dev/rmtn
Yes
No
enabled
/dev/rmtn.1
No
No
enabled
/dev/rmtn.2
Yes
Yes
enabled
/dev/rmtn.3
No
Yes
enabled
/dev/rmtn.4
Yes
No
disabled
/dev/rmtn.5
No
No
disabled
/dev/rmtn.6
Yes
Yes
disabled
/dev/rmtn.7
No
Yes
disabled
The
n
in the filename is the instance number assigned to the drive by the
operating system, where 0 is the first device, 1 is the second and so on.
Rewind on Close
Normally, the drive repositions the tape to BOT (Beginning
of Tape) when the device file is closed. Using the no rewind
option is useful when creating and reading tapes that
contain multiple files.
Retension on Open
Retensioning consists of winding to EOT (End of Tape) and
then rewinding to BOT, in order to reduce errors. If this
option is selected, the tape is positioned at BOT as part of
the open process. Ultrium drives do not require
retensioning, so you should not use device fields that send
retensioning commands.
Compression
Compression can be disabled or enabled.
© 2001, Hewlett-Packard Company