Bc pair activity codes, messages, and descriptions – HP XP Business Copy Software User Manual
Page 84

•
Snapshot XP pairs
•
ShadowImage for z/OS pairs
•
Hitachi FlashCopy Mirroring pairs
•
Auto LUN XP pairs
•
Flex Copy XP pairs
Even if the total number of pairs is less than 500, displaying operation history may take time when
some of the pairs include LUSE volumes.
Table 23 BC pair activity codes, messages, and descriptions
Description
Message
Code
BC initial copy operation started.
PAIR START
4710 - 471F
BC initial copy operation ended, and pair status
changed to PAIR.
PAIR END
4720 - 472F
BC pairsplit operation started, and pair status
changed to COPY(SP) or PSUS(SP).
PSUS START
4730 - 473F
BC pairsplit operation ended, and pair status
changed to PSUS.
PSUS END
4740 - 474F
BC pairresync operation started, and pair status
changed to COPY(RS) or COPY(RS-R).
COPY(RS) STARTCOPY(RS-R)
START
4750 - 475F
BC pairresync operation ended, and pair status
changed to PAIR.
COPY(RS) ENDCOPY(RS-R) END
4760 - 476F
BC pairsplit-S operation was performed, and pair
status changed to SMPL.
SMPL
4780 - 478F
BC pairsplit-E operation was performed, and pair
status changed to PSUE.
PSUE
4790 - 479F
Copy ended with a warning.
COPY WARNING END
47A0 - 47AF
Copy ended abnormally due to P-VOL blockade.
COPY ABNORMAL END(PVOL
BLOCKADE)
47B0 - 47BF
Copy ended abnormally due to S-VOL blockade.
COPY ABNORMAL END(SVOL
BLOCKADE)
47C0 - 47CF
Copy ended abnormally (reason other than above).
COPY ABNORMAL END
47D0 - 47DF
A pair was suspended compulsorily.
COMPULSION PAIR SUSPEND
47E7
Initialization of BC extension table was started (SM
= shared memory).
SI SM INITIALIZATION START
47E9
Initialization of BC extension table was completed
(SM = shared memory).
SI SM INITIALIZATION END
47EA
Initialization of BC extension table failed (SM =
shared memory).
SI SM INITIALIZATION FAILED
47EB
Business Copy XP (BC) for the Array
84