Ft/-fd switches – HP Integrity NonStop H-Series User Manual
Page 36

Running SWID With Customized Switches
Software Identification (SWID) User’s Guide — 527243-004
4 -8
-FT/-FD Switches
In the third example, the version parameter is set to 2 and three files with codes 800,
800, and 101, respectively, are passed. In this example, the Version 2 fingerprint is
computed. The code 101 file generates an error, because the Version 2 fingerprint is
not supported for file code 101.
In the last example, the version parameter is set to .8. As indicated by the error
message, this fingerprint version is invalid.
-FT/-FD Switches
In the following examples, SWID is invoked with the -FT and -FD switches and with
different values specified for the fingerprint type parameter. The -FT switch requests a
specific fingerprint type, and the -FD switch displays the fingerprint type and version.
SMSCM SWIDQA 110> swid -fd -fv -1 c800v1 c800v2
SoftWare Identification Utility - T9298AAL - (12JUL2004) System \CHINOOK
(C)1991 Tandem (C)2004 Hewlett Packard Development Company, L.P.
17Jun 4 05:16:54 (Switches: -FD -FV )
$DSMSCM.SWIDQA
Code Versn Type Original fpts Versn Type Current fpts Diff
----- ----- ----- -------------- ----- ----- ---------------- ----
C800V1 800 1 0 d6e2157129a25d91 2 0 8e00a943ea67b3e0
C800V2 800 2 0 1659667b63d1d2df 2 0 8e00a943ea67b3e0 Yes
$DSMSCM SWIDQA 112> swid -fd -fv 1 c800v1 c800v2
SoftWare Identification Utility - T9298AAL - (12JUL2004) System \CHINOOK
(C)1991 Tandem (C)2004 Hewlett Packard Development Company, L.P.
17Jun 4 05:18:50 (Switches: -FD -FV )
$DSMSCM.SWIDQA
Code Versn Type Original fpts Versn Type Current fpts Diff
----- ----- ----- -------------- ----- ----- ---------------- ----
C800V1 800 1 0 d6e2157129a25d91 1 0 d6e2157129a25d91 No
C800V2 800 2 0 1659667b63d1d2df 1 0 625ae03436920f54
$DSMSCM SWIDQA 113>
$DSMSCM SWIDQA 108> swid -fd -fv 2 c800v1 c800v2 formatc
SoftWare Identification Utility - T9298AAL - (12JUL2004) System \CHINOOK
(C)1991 Tandem (C)2004 Hewlett Packard Development Company, L.P.
17Jun 4 05:13:34 (Switches: -FD -FV )
$DSMSCM.SWIDQA
Code Versn Type Original fpts Versn Type Current fpts Diff
----- ----- ----- -------------- ----- ----- ---------------- ----
C800V1 800 1 0 d6e2157129a25d91 2 0 8e00a943ea67b3e0
C800V2 800 2 0 1659667b63d1d2df 2 0 8e00a943ea67b3e0 Yes
FORMATC 101 ** Not Computed; Fpt version not supported **
$DSMSCM SWIDQA 111> swid -fd -fv .8 c800v1
STOPPED: 0,176
CPU time: 0:00:00.008
Invalid value for -FV : .8