Environmental, Safety, Avaya p330 dc input version – Avaya P332MF User Manual
Page 162: Agency approvals, Emc emissions

Appendix A
Specifications
146
Avaya P332MF User’s Guide
Environmental
Safety
•
UL for US approved according to UL195O Std.
•
C-UL(UL for Canada) approved according to C22.2 No.950 Std.
•
CE for Europe approved according to EN 60950 Std.
•
Laser components are “Class 1 Laser Products”:
— EN-60825/IEC-825-1 for Europe
— FDA 21 CFR 1040.10 and 1040.11 for USA.
•
Overcurrent Protection: A readily accessible listed safety-approved protective
device with a 16A rating must be incorporated in series with building
installation AC power wiring for the equipment under protection.
Avaya P330 DC Input Version
•
Restricted Area Access: This device should only be installed in a restricted
access area.
•
Installation Codes: This device must be installed in accordance with the US
National Electrical Code, Articles 110-26 and 110-27, and the Canadian
Electrical Code, Section 12.
•
Overcurrent Protection: A readily accessible Listed branch-circuit overcurrent
protective device with a 15A rating must be incorporated in the building wiring.
Agency Approvals
EMC Emissions
Approved according to:
•
US - FCC Part 15 Subpart B, Class A
•
EU - EN55022 Class A
•
EU - EN61000-3-2
Output power
dissipation
0.60 W max
Transmit power
-19 dbm min, -14 dbm max
Receive power
-31 dbm max
Operating Temp.
-5 to 50°C (23 to 122°F)
Relative Humidity
5% to 95% non-condensing