Environmental

Safety

UL for US approved according to UL195O Std.

C-UL(UL for Canada) approved according to C22.2 No.950 Std.

CE for Europe approved according to EN 60950 Std.

Laser components are “Class 1 Laser Products”:
— EN-60825/IEC-825-1 for Europe
— FDA 21 CFR 1040.10 and 1040.11 for USA.

Overcurrent Protection: A readily accessible listed safety-approved protective
device with a 16A rating must be incorporated in series with building
installation AC power wiring for the equipment under protection.

Avaya P330 DC Input Version

Restricted Area Access: This device should only be installed in a restricted
access area.

Installation Codes: This device must be installed in accordance with the US
National Electrical Code, Articles 110-26 and 110-27, and the Canadian
Electrical Code, Section 12.

Overcurrent Protection: A readily accessible Listed branch-circuit overcurrent
protective device with a 15A rating must be incorporated in the building wiring.

Agency Approvals

EMC Emissions

Approved according to:

US - FCC Part 15 Subpart B, Class A

EU - EN55022 Class A

EU - EN61000-3-2

Output power
dissipation

0.60 W max

Transmit power

-19 dbm min, -14 dbm max

Receive power

-31 dbm max

Operating Temp.

-5 to 50°C (23 to 122°F)

Relative Humidity