beautypg.com

Adaptec SATA AND SCSI RAID CONTROLLERS User Manual

Page 99

background image

C-6

Adaptec Flash Utility (AFU)

SAVE

The SAVE command saves the contents of a controller’s flash in a
UFI file. The name of the UFI file is based on the controller type
and cannot be changed.

You must restart the computer following a SAVE command.

Command Syntax

The command syntax for the SAVE command is as follows:

AFU SAVE [/C] [/D ]

Command Switches

The following switches are available:

/C

is one or more controller IDs representing

the set of controllers on which to perform the specified
command. The default is 0, which means that if the computer
has multiple controllers, the AFU defaults to controller 0 unless you
specify otherwise.

You can specify a single controller ID, for example:

/C 0

multiple IDs separated by commas, for example:

/C 0,2

or ALL to indicate all controllers.

Note:

If the controller you want using the e /C switch;

otherwise, the AFU displays an error message and exits.

/D

specifies the path (drive and directory)

where the UFI files are located. If you do not specify the /D
switch, the AFU looks for, or creates, its UFI files in the default
location.

Note:

You cannot specify the name of a UFI file, only its path.

UFI filenames are predefined, based on the controller type.